KINETIC-ENERGY EFFECTS IN AN ION ENSEMBLE SUBJECTED TO MASS-SELECTIVE ISOLATION AND RESONANCE EXCITATION - A SIMULATION STUDY

被引:14
作者
MARCH, RE
WEIR, MR
TKACZYK, M
LONDRY, FA
ALFRED, RL
FRANKLIN, AM
TODD, JFJ
机构
[1] TRENT UNIV,DEPT PHYS,PETERBOROUGH K9J 7B8,ONTARIO,CANADA
[2] UNIV KENT,CHEM LAB,CANTERBURY CT2 7NH,KENT,ENGLAND
来源
ORGANIC MASS SPECTROMETRY | 1993年 / 28卷 / 05期
关键词
D O I
10.1002/oms.1210280506
中图分类号
O62 [有机化学];
学科分类号
070303 ; 081704 ;
摘要
A simulation study is described of the behaviour of ions confined in a quadrupole ion trap during each of two separate operations of a tandem mass spectrometric experiment. The two operations are those of mass-selective ion isolation and mass-selective resonance excitation to the point of ion ejection from the ion trap. The method of mass-selective ion isolation simulated is that of consecutive ion isolation. Simulation data indicate that the collisional history of the ions prior to the isolation process can greatly influence the degree to which ions survive this process. Simulation data for mass-selective resonance ejection are compared with experimental data obtained with a Finnigan-MAT ion trap mass spectrometer. In each operation, the facility with which ions absorb energy from the field within the ion trap, whether this field is derived from the R.F. drive potential or a supplementary potential, can determine the extent to which ions are retained within the ion trap during the two mass-selective operations described.
引用
收藏
页码:499 / 509
页数:11
相关论文
共 30 条
[1]   THE ION-TRAP MASS-SPECTROMETER IN ION STRUCTURE STUDIES - THE CASE OF [M-H]+ IONS FROM CHALCONE [J].
ARDANAZ, CE ;
TRALDI, P ;
VETTORI, U ;
KAVKA, J ;
GUIDUGLI, F .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (01) :5-10
[2]   DERIVATIONS OF FIELD EQUATIONS AND STABILITY PARAMETERS FOR 3 OPERATING MODES OF 3-DIMENSIONAL QUADRUPOLE [J].
BONNER, RF .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1977, 23 (04) :249-257
[3]   ION TRAP MASS-SPECTROMETRY [J].
COOKS, RG ;
GLISH, GL ;
MCLUCKEY, SA ;
KAISER, RE .
CHEMICAL & ENGINEERING NEWS, 1991, 69 (12) :26-&
[4]   QUADRUPOLE ION TRAP MASS-SPECTROMETRY [J].
COOKS, RG ;
KAISER, RE .
ACCOUNTS OF CHEMICAL RESEARCH, 1990, 23 (07) :213-219
[5]  
DUCATI A, 1960, Patent No. 2929952
[6]  
DUSHMAN S, 1962, SCI F VACUUM TECHNIQ, P323
[7]   NEW MODE OF OPERATION FOR 3-DIMENSIONAL QUADRUPOLE ION STORE (QUISTOR) - SELECTIVE ION REACTOR [J].
FULFORD, JE ;
MARCH, RE .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1978, 26 (02) :155-162
[8]   RECENT ADVANCES IN ION-TRAP TECHNOLOGY [J].
GRIFFITHS, IW .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :69-73
[9]   A STUDY OF RELEVANT PARAMETERS IN COLLISIONAL-ACTIVATION OF IONS IN THE ION-TRAP MASS-SPECTROMETER [J].
GRONOWSKA, J ;
PARADISI, C ;
TRALDI, P ;
VETTORI, U .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (09) :306-313
[10]   THE GENERAL-FORM OF THE QUADRUPOLE ION TRAP POTENTIAL [J].
KNIGHT, RD .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1983, 51 (01) :127-131