A LABORATORY CT SCANNER FOR DYNAMIC IMAGING

被引:6
作者
DRANGOVA, M [1 ]
FENSTER, A [1 ]
机构
[1] UNIV WESTERN ONTARIO,DEPT MED BIOPHYS,LONDON N6A 3K7,ONTARIO,CANADA
关键词
DYNAMIC COMPUTED TOMOGRAPHY; QUANTITATIVE COMPUTED TOMOGRAPHY; IMAGE INTENSIFIER;
D O I
10.1118/1.597332
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A high-resolution laboratory CT scanner has been developed for imaging objects undergoing periodic motion. The scanner comprises an x-ray image intensifier, optically coupled to a linear photodiode array. Gated time-evolved projections of a single slice of the moving object are acquired, reformatted, and reconstructed. The resulting series of CT images shows the object at different phases of its motion cycle. The scanner has an adjustable field of view (FOV) and the resolution can be as high as 3.2 mm-1 (for the 40-mm FOV). The spatial resolution depends on the inherent resolution of the scanner and on the object's velocity. For objects moving at 1 cm s-1, the spatial resolution is reduced by 9% in the direction of motion. The signal intensity in the reconstructed image is linear for materials with attenuation coefficients as high as 1.5 cm-1 (for a 90-kVp x-ray beam), with an average accuracy of +/-0.02 cm-1. The average accuracy of circumference measurements made from the CT images is +/-0.3 mm. Lastly, an application of this dynamic CT scanner to imaging excised human arterial specimens under simulated physiological pressure conditions is presented as an example.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 35 条
[1]  
BARNES GT, 1979, P SOC PHOTO-OPT INS, V173, P225
[2]  
BENDAT JS, 1986, RANDOM DATA ANAL MEA, P53
[3]   ANALYSIS AND CORRECTION OF IMPERFECTIONS IN THE IMAGE INTENSIFIER-TV-DIGITIZER IMAGING CHAIN [J].
BOONE, JM ;
SEIBERT, JA ;
BARRETT, WA ;
BLOOD, EA .
MEDICAL PHYSICS, 1991, 18 (02) :236-242
[4]   PROPOSED DYNAMIC CARDIAC 3-D DENSITOMETER FOR EARLY DETECTION AND EVALUATION OF HEART-DISEASE [J].
BOYD, DP ;
GOULD, RG ;
QUINN, JR ;
SPARKS, R ;
STANLEY, JH ;
HERRMANNSFELDT, WB .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (02) :2724-2726
[5]  
BROOKS R A, 1976, Medical Physics (Woodbury), V3, P237, DOI 10.1118/1.594240
[6]   A PHOTODIODE ARRAY X-RAY-IMAGING SYSTEM FOR DIGITAL ANGIOGRAPHY [J].
CUNNINGHAM, IA ;
FENSTER, A .
MEDICAL PHYSICS, 1984, 11 (03) :303-310
[7]  
DRANGOVA M, 1990, P SOC PHOTO-OPT INS, V1231, P255, DOI 10.1117/12.18835
[8]   ELASTICITY AND GEOMETRY MEASUREMENTS OF VASCULAR SPECIMENS USING A HIGH-RESOLUTION LABORATORY CT SCANNER [J].
DRANGOVA, M ;
HOLDSWORTH, DW ;
BOYD, CJ ;
DUNMORE, PJ ;
ROACH, MR ;
FENSTER, A .
PHYSIOLOGICAL MEASUREMENT, 1993, 14 (03) :277-290
[9]  
DRANGOVA M, 1993, MED PHYS, V20, P1623
[10]   NOISE AND CONTRAST DETECTION IN COMPUTED-TOMOGRAPHY IMAGES [J].
FAULKNER, K ;
MOORES, BM .
PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (04) :329-339