HYDROGEN DETECTION IN METALS BY NEUTRON INTERFEROMETRY

被引:9
作者
RAUCH, H
SEIDL, E
ZEILINGER, A
BAUSPIESS, W
BONSE, U
机构
[1] Atominstitut der Österreichischen Universitäten
[2] Institut für Physik
[3] Institut Laue Langevin, F-38042 Grenoble
关键词
D O I
10.1063/1.325195
中图分类号
O59 [应用物理学];
学科分类号
摘要
The neutron interferometer is used to determine the H and D concentration in V and Nb samples. The hydrogen content changes the average coherent scattering length and, therefore, the phase shift of the coherent beams which can be measured precisely. The results are compared with the weighing and the epithermal neutron scattering method. Characteristic values for the sensitivity obtained with the interferometer method are 0.02-0.06 at.% or 6-12 ppm by weight. As soon as precipitation occurs in the sample, a loss of contrast indicates additional small-angle scattering.
引用
收藏
页码:2731 / 2734
页数:4
相关论文
共 24 条
[1]  
Alefeld G., 1975, Comments on Solid State Physics, V6, P53
[2]  
Alefeld G, 1975, DIFFUSION SOLIDS REC, P231
[3]  
Bauspiess W., 1976, P C NEUTRON SCATTERI, VII, P1094
[4]  
BOES N, 1976, Z NATURFORSCH A, V31, P760
[5]  
BONSE U, 1967, SMALL ANGLE XRAY SCA, P121
[6]  
Fromm E., 1976, GASE KOHLENSTOFF MET
[7]   DIFFUSION-COEFFICIENT, HEAT OF TRANSPORT, AND SOLUBILITY LIMIT OF H IN V [J].
HELLER, R ;
WIPF, H .
PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1976, 33 (02) :525-529
[8]  
KOESTER L, 1971, Z ANGEW PHYSIK, V31, P21
[9]  
KOESTER L, 1977, NEUTRON SCATTERING L
[10]   HYDROGEN AND ENERGY-SYSTEMS [J].
MARCHETTI, C .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1976, 1 (01) :3-10