REPRODUCIBILITY OF QUANTITATIVE MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY

被引:28
作者
SHAPIRO, JR
REISNER, SA
AMICO, AF
KELLY, PF
MELTZER, RS
机构
[1] UNIV ROCHESTER,MED CTR,MED CTR,DEPT ANESTHESIOL,BOX 679,ROCHESTER,NY 14642
[2] UNIV ROCHESTER,MED CTR,DEPT MED,ROCHESTER,NY 14642
[3] UNIV ROCHESTER,MED CTR,CTR BIOMED ULTRASOUND,ROCHESTER,NY 14642
关键词
D O I
10.1016/0735-1097(90)90634-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To determine whether myocardial contrast echocardiography is quantitatively reproducible, repeated intracoronary injections of sonicated albumin (5%) were performed in eight open chest dogs. Paired injections were performed at baseline, during ischemia produced by ligation of a coronary artery, and during hyperemia induced by intravenous infusion of 0.75 mg/kg body weight of dipyridamole. Contrast washout curves were generated for the left anterior descending coronary artery territory (ischemic area) and left circumflex coronary artery territory (nonischemic area) by beat per beat analysis of frozen end-diastolic frames of left ventricular short-axis views. Peak contrast intensity, contrast washout half-time and area under the curve were derived from these curves. A total of 75 contrast washout curves were analyzed for the study of interinjection, intraobserver and interobserver reproducibility. The correlation coefficients between measurements obtained from paired injections of the echocardiographic contrast agent (interinjection reproducibility) ranged from 0.78 for peak contrast intensity to 0.87 for area under the curve. Percent error varied between 14.7% and 24.7%. The intraobserver variability in measurements was less than the interinjection variability, with a cumulative mean percent error of 17.8% and correlation coefficients of 0.72 (peak contrast intensity), 0.95 (area under the curve) and 0.96 (washout half-time). Interobserver correlation for all indexes was high (r = 0.92 to 0.96). It is concluded that peak contrast intensity, contrast washout half-time and the area under the curve derived from myocardial contrast washout curves can be measured reproducibly from videotapes. In addition, the variability between two injections attempted under identical conditions is greater than reader variability from videotapes. © 1990.
引用
收藏
页码:602 / 609
页数:8
相关论文
共 34 条
[1]   ASSESSMENT OF MYOCARDIAL PERFUSION ABNORMALITIES WITH CONTRAST-ENHANCED TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
ARMSTRONG, WF ;
MUELLER, TM ;
KINNEY, EL ;
TICKNER, EG ;
DILLON, JC ;
FEIGENBAUM, H .
CIRCULATION, 1982, 66 (01) :166-173
[2]   ASSESSMENT OF LOCATION AND SIZE OF MYOCARDIAL-INFARCTION WITH CONTRAST-ENHANCED ECHOCARDIOGRAPHY .2. APPLICATION OF DIGITAL IMAGING TECHNIQUES [J].
ARMSTRONG, WF ;
WEST, SR ;
DILLON, JC ;
FEIGENBAUM, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (01) :141-148
[3]   ASSESSMENT OF LOCATION AND SIZE OF MYOCARDIAL-INFARCTION WITH CONTRAST-ENHANCED ECHOCARDIOGRAPHY [J].
ARMSTRONG, WF ;
WEST, SR ;
MUELLER, TM ;
DILLON, JC ;
FEIGENBAUM, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1983, 2 (01) :63-69
[4]  
ARMSTRONG WF, 1986, ECHOCARDIOGR-J CARD, V3, P355
[5]   ASSESSMENT OF MYOCARDIAL PERFUSION IN HUMANS BY CONTRAST ECHOCARDIOGRAPHY .1. EVALUATION OF REGIONAL CORONARY RESERVE BY PEAK CONTRAST INTENSITY [J].
CHEIRIF, J ;
ZOGHBI, WA ;
RAIZNER, AE ;
MINOR, ST ;
WINTERS, WL ;
KLEIN, MS ;
DEBAUCHE, TL ;
LEWIS, JM ;
ROBERTS, R ;
QUINONES, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) :735-743
[6]   CONTRAST ECHOCARDIOGRAPHY DURING CORONARY ARTERIOGRAPHY IN HUMANS - PERFUSION AND ANATOMIC STUDIES [J].
FEINSTEIN, SB ;
LANG, RM ;
DICK, C ;
NEUMANN, A ;
ALSADIR, J ;
CHUA, KG ;
CARROLL, J ;
FELDMAN, T ;
BOROW, KM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (01) :59-65
[7]   TWO-DIMENSIONAL CONTRAST ECHOCARDIOGRAPHY .1. INVITRO DEVELOPMENT AND QUANTITATIVE-ANALYSIS OF ECHO CONTRAST AGENTS [J].
FEINSTEIN, SB ;
TENCATE, FJ ;
ZWEHL, W ;
ONG, K ;
MAURER, G ;
TEI, C ;
SHAH, PM ;
MEERBAUM, S ;
CORDAY, E .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 3 (01) :14-20
[8]   EXPERIENCE WITH MECHANICAL CONTRAST-MEDIUM INJECTION AT SELECTIVE CORONARY ANGIOGRAPHY [J].
FRANKEN, G ;
ZEITLER, E .
CARDIOVASCULAR RADIOLOGY, 1978, 1 (01) :21-26
[9]   CONTRAST PERFUSION ECHOCARDIOGRAPHY - DISTRIBUTION AND REPRODUCIBILITY OF MYOCARDIAL CONTRAST ENHANCEMENT IN CORONARY-ARTERY DISEASE [J].
GRIFFIN, B ;
TIMMIS, AD ;
SOWTON, E .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (07) :538-543
[10]   CONTRAST PERFUSION ECHOCARDIOGRAPHY - IDENTIFICATION OF AREA AT RISK OF DYSKINESIS DURING PERCUTANEOUS TRANS-LUMINAL CORONARY ANGIOPLASTY [J].
GRIFFIN, B ;
TIMMIS, AD ;
HENDERSON, RA ;
SOWTON, E .
AMERICAN HEART JOURNAL, 1987, 114 (03) :497-502