REGISTRATION OF 3-DIMENSIONAL MR AND PET IMAGES OF THE HUMAN BRAIN WITHOUT MARKERS

被引:82
作者
KAPOULEAS, I
ALAVI, A
ALVES, WM
GUR, RE
WEISS, DW
机构
[1] UNIV PENN,DIV NUCL MED,DEPT RADIOL,PHILADELPHIA,PA 19104
[2] UNIV PENN,DEPT NEUROSURG,PHILADELPHIA,PA 19104
[3] UNIV PENN,DEPT PSYCHIAT,PHILADELPHIA,PA 19104
关键词
BRAIN; ANATOMY; MR STUDIES; EMISSION CT; IMAGES; DISPLAY; PROCESSING; MAGNETIC RESONANCE (MR); IMAGE DISPLAY; IMAGE PROCESSING; RADIONUCLIDE IMAGING; COMPUTER-ASSISTED;
D O I
10.1148/radiology.181.3.1947089
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Axial and sagittal magnetic resonance (MR) sections and contiguous sections of axial positron emission tomographic (PET) images obtained with fludeoxyglucose F-18 were used to evaluate a new method of registering three-dimensional images of the brain. The users specified the inter-hemispheric fissure plane in three dimensions for both the MR and PET data sets by specifying its endpoints within several axial sections. A transformation matrix aligning the interhemispheric fissure plane in MR and PET space was calculated and used to create one resectioned PET image for each MR sagittal image. The system overlaid outlines of the MR image on the resectioned PET image, and the user specified the remaining translations and rotation by moving the overlaid outline of the MR image. MR and PET data sets in four subjects were registered. The three-dimensional error on average was less than 3.8 mm and never exceeded 7.5 mm. Less than 1 hour per patient was required for registration. The method is accurate unless the interhemispheric fissure deviates significantly from a planar configuration. It does not need thin or contiguous MR sections and provides an estimate of the total registration error for every case.
引用
收藏
页码:731 / 739
页数:9
相关论文
共 19 条
[1]  
BAJCY R, 1988, EVALUATION GLOBAL RE
[2]  
DRANGOVA M, 1987, THESIS MCGILL U TORO
[3]  
EVANS, 1989, MED IMAGING 3, V1092, P264
[4]   ANATOMICAL-FUNCTIONAL CORRELATION USING AN ADJUSTABLE MRI-BASED REGION OF INTEREST ATLAS WITH POSITRON EMISSION TOMOGRAPHY [J].
EVANS, AC ;
BEIL, C ;
MARRETT, S ;
THOMPSON, CJ ;
HAKIM, A .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1988, 8 (04) :513-530
[5]  
FELLER W, 1957, INTRO PROBABILITY TH, pCH9
[6]   A STEREOTACTIC METHOD OF ANATOMICAL LOCALIZATION FOR POSITRON EMISSION TOMOGRAPHY [J].
FOX, PT ;
PERLMUTTER, JS ;
RAICHLE, ME .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :141-153
[7]   LOCALIZATION IN PET IMAGES - DIRECT FITTING OF THE INTERCOMMISSURAL (AC-PC) LINE [J].
FRISTON, KJ ;
PASSINGHAM, RE ;
NUTT, JG ;
HEATHER, JD ;
SAWLE, GV ;
FRACKOWIAK, RSJ .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (05) :690-695
[8]  
KAPOULEAS I, 1991, 179 U PENNS DEP RAD
[9]  
KAPOULEAS I, 1990, 10TH P INT C PATT RE, P583
[10]  
KAPOULEAS I, 1989, 13TH P ANN S COMP AP, P739