COMPARISON OF INSPIRATORY WORK OF BREATHING BETWEEN FLOW-TRIGGERED AND PRESSURE-TRIGGERED DEMAND FLOW SYSTEMS IN RABBITS

被引:14
作者
NISHIMURA, M
IMANAKA, H
YOSHIYA, I
KACMAREK, RM
机构
[1] OSAKA UNIV,SCH MED,DEPT ANESTHESIOL,OSAKA 553,JAPAN
[2] OSAKA UNIV HOSP,INTENS CARE UNIT,OSAKA 553,JAPAN
关键词
VENTILATOR; PRESSURE SUPPORT VENTILATION; NEONATE; WORK OF BREATHING; INTUBATION; ENDOTRACHEAL; MECHANICAL VENTILATION; PULMONARY EMERGENCIES; CRITICAL ILLNESS; PEDIATRICS;
D O I
10.1097/00003246-199406000-00020
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: Flow-triggered continuous positive airway pressure decreases the inspiratory work of breathing in adults when compared with pressure-triggered continuous positive airway pressure. However, the effect of flow-triggered continuous positive airway pressure on work of breathing in neonates is not known. Our objective was to determine if flow triggering was superior to pressure triggering in the presence of narrow endotracheal tubes, such as those tubes used in neonates. Design: Prospective evaluation using within-animal comparison of flow-triggering and pressure-triggering demand flow systems. Setting: The animal laboratory in a university hospital. Subjects: Six spontaneously breathing white rabbits, tracheostomized and intubated with 3- and 4-mm inner diameter endotracheal tubes. Interventions: The animals were connected to a ventilator through a standard respiratory circuit. The ventilator was randomly operated in the following modes: flow-triggered continuous positive ah-way pressure, pressure-triggered continuous positive airway pressure, flow-triggered with 5 cm H2O pressure support ventilation, and pressure-triggered with 5 cm H2O pressure support ventilation. Measurements and Main Results: Esophageal pressure, airway pressure, and flow signals were monitored. Control data were obtained while the rabbits were breathing room air through the endotracheal tube. With 3-mm inner diameter endotracheal tubes, the negative deflection of esophageal pressure during flow-triggered continuous positive airway pressure was significantly less than control; however, negative deflection of esophageal pressure during pressure-triggered continuous positive airway pressure did not significantly differ from control The application of 5 cm H2O pressure support ventilation with flow-triggering decreased negative deflection of esophageal pressure significantly compared with flow-triggered continuous positive airway pressure, pressure-triggered continuous positive airway pressure, and control. With endotracheal tube inner diameter of 4 mm, flow-triggered continuous positive airway pressure and pressure-triggered continuous positive airway pressure did not show any differences compared to control. Negative deflection of esophageal pressure differed under ah conditions except control when results with the 3-mm inner diameter endotracheal tube were compared with the 4-mm inner diameter endotracheal tube. Conclusions: Flow-triggering is superior to pressure-triggering in the presence of a 3-mm inner diameter endotracheal tube. This difference was not clear with a 4-mm inner diameter endotracheal tube. The size of the endotracheal tube may be the most important variable in evaluating the approach used to ventilate small neonates.
引用
收藏
页码:1002 / 1009
页数:8
相关论文
共 25 条
[1]   MEASUREMENT OF PLEURAL PRESSURE IN NEONATES [J].
ASHER, MI ;
COATES, AL ;
COLLINGE, JM ;
MILICEMILJ, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (02) :491-494
[2]   INSPIRATORY WORK OF BREATHING DURING SPONTANEOUS VENTILATION USING DEMAND VALVES AND CONTINUOUS-FLOW SYSTEMS [J].
BEYDON, L ;
CHASSE, M ;
HARF, A ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1988, 138 (02) :300-304
[3]   INSPIRATORY PRESSURE SUPPORT PREVENTS DIAPHRAGMATIC FATIGUE DURING WEANING FROM MECHANICAL VENTILATION [J].
BROCHARD, L ;
HARF, A ;
LORINO, H ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1989, 139 (02) :513-521
[4]   IMPROVED EFFICACY OF SPONTANEOUS BREATHING WITH INSPIRATORY PRESSURE SUPPORT [J].
BROCHARD, L ;
PLUSKWA, F ;
LEMAIRE, F .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1987, 136 (02) :411-415
[5]  
CHATBURN R L, 1991, Respiratory Care, V36, P569
[6]   LIQUID-FILLED ESOPHAGEAL CATHETER FOR MEASURING PLEURAL PRESSURE IN PRETERM NEONATES [J].
COATES, AL ;
DAVIS, GM ;
VALLINIS, P ;
OUTERBRIDGE, EW .
JOURNAL OF APPLIED PHYSIOLOGY, 1989, 67 (02) :889-893
[7]   INVESTIGATION OF THE SPONTANEOUS MODES OF BREATHING OF DIFFERENT VENTILATORS [J].
COX, D ;
TINLOI, SF ;
FARRIMOND, JG .
INTENSIVE CARE MEDICINE, 1988, 14 (05) :532-537
[8]  
GERHARDT T, 1989, J PEDIATR, V144, P120
[9]   COMPARISON OF WORK OF BREATHING ON HIGH GAS-FLOW AND DEMAND VALVE CONTINUOUS POSITIVE AIRWAY PRESSURE SYSTEMS [J].
GIBNEY, RTN ;
WILSON, RS ;
PONTOPPIDAN, H .
CHEST, 1982, 82 (06) :692-695
[10]   PATIENT TRIGGERED VENTILATION IN PREMATURE NEONATES [J].
GREENOUGH, A ;
GREENALL, F .
ARCHIVES OF DISEASE IN CHILDHOOD, 1988, 63 (01) :77-78