BACKGROUND-CORRECTED SIMULTANEOUS MULTIELEMENT ATOMIC-ABSORPTION SPECTROMETER

被引:129
作者
HARNLY, JM
OHAVER, TC
GOLDEN, B
WOLF, WR
机构
[1] UNIV MARYLAND,COLLEGE PK,MD 20742
[2] USDA,NUTRIENT COMPOSIT LAB,BELTSVILLE,MD 20705
关键词
D O I
10.1021/ac50048a027
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multielement atomic absorption spectrometer has been developed based on a continuum source and an echelle polychromator modified for wavelength modulation (SIMAAC). The instrument is capable of measuring up to 16 elements simultaneously with either flame or electrothermal atomization. Double beam operation and dynamic background correction are achieved on all channels. Approximately 100 absorbances are calculated per second per channel. Detection limits for SIMAAC with electrothermal atomization are comparable to the single element mode of operation and to commercially available AA instruments using electrothermal atomization. © 1979, American Chemical Society. All rights reserved.
引用
收藏
页码:2007 / 2014
页数:8
相关论文
共 34 条
[1]   DESIGN AND DEVELOPMENT OF A MULTICHANNEL ATOMIC-ABSORPTION SPECTROMETER FOR SIMULTANEOUS DETERMINATION OF TRACE-METALS IN HAIR [J].
ALDER, JF ;
ALGER, D ;
SAMUEL, AJ ;
WEST, TS .
ANALYTICA CHIMICA ACTA, 1976, 87 (02) :301-311
[2]   SIMULTANEOUS DETERMINATION OF 7 TRACE-METALS IN POTABLE WATER USING A VIDICON ATOMIC-ABSORPTION SPECTROMETER [J].
ALDOUS, KM ;
MITCHELL, DG ;
JACKSON, KW .
ANALYTICAL CHEMISTRY, 1975, 47 (07) :1034-1037
[3]  
BARNETT WB, 1974, ATOM ABSORPT NEWSL, V13, P56
[4]   STUDIES OF AN INDUCTIVELY-COUPLED HIGH-FREQUENCY ARGON PLASMA FOR OPTICAL EMISSION SPECTROMETRY .2. COMPROMISE CONDITIONS FOR SIMULTANEOUS MULTIELEMENT ANALYSIS [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1975, 30 (09) :309-334
[5]   EXPERIMENTAL-STUDY OF A 1-KW, 50-MHZ RF INDUCTIVELY COUPLED PLASMA WITH PNEUMATIC NEBULIZER, AND A DISCUSSION OF EXPERIMENTAL-EVIDENCE FOR A NONTHERMAL MECHANISM [J].
BOUMANS, PWJM ;
DEBOER, FJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1977, 32 (9-10) :365-395
[6]   PRECISION OF FLAME ATOMIC-ABSORPTION MEASUREMENTS OF ARSENIC, CADMIUM, CALCIUM, COPPER, IRON, MAGNESIUM, MOLYBDENUM, SODIUM, AND ZINC [J].
BOWER, NW ;
INGLE, JD .
ANALYTICAL CHEMISTRY, 1977, 49 (04) :574-579
[7]   SPECTRAL AND NOISE CHARACTERISTICS OF A 300-WATT EIMAC ARC LAMP [J].
COCHRAN, RL ;
HIEFTJE, GM .
ANALYTICAL CHEMISTRY, 1977, 49 (13) :2040-2043
[8]  
EDIGER RD, 1978, 29TH PITTSB C AN CHE
[9]  
FASSEL VA, 1975, ANAL CHEM, V47, P1110
[10]  
FASSEL VA, 1977, SPECTROCHIM ACTA B, V32, P327