HELICAL CT OF THE LIVER - CLINICAL-APPLICATION OF AN AUTOMATED COMPUTER TECHNIQUE, SMARTPREP, FOR OBTAINING IMAGES WITH OPTIMAL CONTRAST ENHANCEMENT

被引:74
作者
SILVERMAN, PM [1 ]
ROBERTS, S [1 ]
TEFFT, MC [1 ]
BROWN, B [1 ]
FOX, SH [1 ]
COOPER, C [1 ]
ZEMAN, RK [1 ]
机构
[1] GE CO,MED SYST,MILWAUKEE,WI 53201
关键词
D O I
10.2214/ajr.165.1.7785637
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVES. The purpose of this study was to evaluate an automated computer technique (SmartPrep) for achieving a consistently high level of contrast enhancement in the liver with helical CT. The technique compensates for variability between patients by indicating graphically the time at which scanning should be initiated to reach a desired level of hepatic enhancement. MATERIALS AND METHODS. One hundred nine consecutive patients undergoing helical CT of the abdomen were randomly evaluated, using either a standard 70-sec delay from the start of the injection of contrast material to scanning or a newly developed, commercially available automated technique, SmartPrep, A series of multiple low-dose scans was performed until an arbitrary threshold of hepatic enhancement (50 H) over baseline was achieved. Three regions of interest (ROIs) were imaged on a baseline scan and on contrast-enhanced scans at the upper, mid, and lower liver. Average hepatic enhancement and the standard deviation over baseline was calculated for each group at all anatomic levels. For the SmartPrep group, the range of time between scan initiation and onset of scanning was calculated. RESULTS. The mean hepatic enhancement for the control group (n = 56) was 59.8 +/- 20.1 H, which differed significantly (p = .0002) from that for the SmartPrep group (n = 53), which was 71.6 +/- 15.2 H. Comparison of the variability between the two groups' enhancement levels was also significant (p = .02). The range of delay times for the SmartPrep group was 48-86 sec. In two additional cases, abnormal graphically displayed enhancement curves were the first indication of an improper injection. CONCLUSION. Use of SmartPrep yields a greater and more consistent level of hepatic enhancement from patient to patient than does use of a conventional fixed delay time. The ability to scan more efficiently to achieve greater hepatic enhancement using SmartPrep has significant implications for potential contrast cost savings.
引用
收藏
页码:73 / 78
页数:6
相关论文
共 21 条
[1]   UNDERSTANDING AND OPTIMIZING USE OF CONTRAST MATERIAL FOR CT OF THE LIVER [J].
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (02) :323-331
[2]  
BERLAND LL, 1992, AJR, V138, P853
[3]   SPIRAL CT OF THE LIVER [J].
BLUEMKE, DA ;
FISHMAN, EK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (04) :787-792
[4]   COST-EFFECTIVE USE OF LOW-OSMOLALITY CONTRAST-MEDIA FOR CT OF THE LIVER - EVALUATION OF LIVER ENHANCEMENT PROVIDED BY VARIOUS DOSES OF IOHEXOL [J].
BREE, RL ;
PARISKY, YR ;
BERNARDINO, ME ;
COSTELLO, P ;
LEDER, R ;
BROWN, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) :579-583
[5]   BOLUS GEOMETRY AND DYNAMICS AFTER INTRAVENOUS CONTRAST-MEDIUM INJECTION [J].
CLAUSSEN, CD ;
BANZER, D ;
PFRETZSCHNER, C ;
KALENDER, WA ;
SCHORNER, W .
RADIOLOGY, 1984, 153 (02) :365-368
[6]   ASSESSMENT OF THE THORACIC AORTA BY SPIRAL CT [J].
COSTELLO, P ;
ECKER, CP ;
TELLO, R ;
HARTNELL, GG .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (05) :1127-1130
[7]   HEPATIC CT CONTRAST ENHANCEMENT - EFFECT OF DOSE, DURATION OF INFUSION, AND TIME ELAPSED FOLLOWING INFUSION [J].
DEAN, PB ;
VIOLANTE, MR ;
MAHONEY, JA .
INVESTIGATIVE RADIOLOGY, 1980, 15 (02) :158-161
[8]   INVESTIGATION OF CONTRAST ENHANCEMENT IN CT OF THE LIVER - THE NEED FOR IMPROVED METHODS [J].
DODD, GD ;
BARON, RL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) :643-645
[9]   CONTRAST ENHANCEMENT TECHNIQUE FOR DYNAMIC HEPATIC COMPUTED TOMOGRAPHIC SCANNING [J].
FOLEY, WD ;
BERLAND, LL ;
LAWSON, TL ;
SMITH, DF ;
THORSEN, MK .
RADIOLOGY, 1983, 147 (03) :797-803
[10]   DYNAMIC HEPATIC CT [J].
FOLEY, WD .
RADIOLOGY, 1989, 170 (03) :617-622