RAPID MR MEASUREMENT OF CONTRAST-MEDIUM DILUTION KINETICS (GADOLINIUM-DTPA) IN A FLOW PHANTOM

被引:9
作者
BOCK, JC [1 ]
SANDER, B [1 ]
FRANK, J [1 ]
SCHORNER, W [1 ]
机构
[1] FREE UNIV BERLIN,RUDOLF VIRCHOW KLIN,CHIRURG KLIN & POLIKLIN,W-1000 BERLIN 19,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1991年 / 155卷 / 03期
关键词
INDICATOR DILUTION METHOD; PARAMAGNETIC CONTRAST MEDIA; MAGNETIC RESONANCE IMAGING; GRADIENT ECHO (FLASH);
D O I
10.1055/s-2008-1033259
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We studied first-pass MRI-contrast dilution to compute flow and volume of distribution in a realistic flow phantom. Pulsatile flow was provided by a one-chamber artificial heart. Physiological stroke volume, rate, pressure, and flow were adjustable. An elastic tube with dimensions similar to that of the human aorta was imaged at a rate of 2.4 Hz. After contrast injection, an initial increase in signal intensity was followed by a decrease. Signal-intensity-time plots demonstrated slightly skewed curves as expected from dispersion theory. After calibration at different gadolinium-DTPA concentrations, signal intensities were converted into true gadolinium concentrations, and flow was calculated from the concentration-time curves. Flow was varied between 2.5 and 10.0 l/min and a significant correlation was found between the MRI-estimate and true flow. Volume of distribution between injection and detection site was reliably estimated. This study demonstrates rapid 2-D imaging of a paramagnetic contrast bolus in a realistic flow phantom. Reliable estimates of flow and volume are obtained.
引用
收藏
页码:267 / 271
页数:5
相关论文
共 11 条
  • [1] 1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING
    ATKINSON, DJ
    BURSTEIN, D
    EDELMAN, RR
    [J]. RADIOLOGY, 1990, 174 (03) : 757 - 762
  • [2] THERMAL RECOVERY AFTER PASSAGE OF THE PULMONARY CIRCULATION ASSESSED BY DECONVOLUTION
    BOCK, J
    DEUFLHARD, P
    HOEFT, A
    KORB, H
    WOLPERS, HG
    STEINMANN, J
    HELLIGE, G
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1988, 64 (03) : 1210 - 1216
  • [3] NO PULMONARY-EDEMA OR CONGESTION AFTER CENTRAL VENOUS INJECTION OF CONVENTIONAL AND NEWER CONTRAST-MEDIA IN DOGS
    BOCK, J
    HEILBRON, DC
    HOEFT, A
    KORB, H
    HELLIGE, G
    [J]. INVESTIGATIVE RADIOLOGY, 1988, 23 (11) : 836 - 841
  • [4] BOCK JC, 1990, INVEST RADIOL, V25, P938
  • [5] BOCK JC, 1990, 19 ANN M SOC MAGN RE
  • [6] INDICATOR DILUTION TIME-ACTIVITY CURVES DEMONSTRATED BY RAPID MAGNETIC-RESONANCE IMAGING TECHNIQUES AND PARAMAGNETIC CONTRAST AGENT
    DAVIS, PL
    WOLF, GL
    GILLEN, JS
    [J]. INVESTIGATIVE RADIOLOGY, 1989, 24 (05) : 400 - 406
  • [7] FRANK J, 1979, BIOMED TECHNIK, V24, P307
  • [8] FRESTIN GP, 1988, DIAGN IMAG INT S, V40
  • [9] DYNAMIC IMAGING WITH LANTHANIDE CHELATES IN NORMAL BRAIN - CONTRAST DUE TO MAGNETIC-SUSCEPTIBILITY EFFECTS
    VILLRINGER, A
    ROSEN, BR
    BELLIVEAU, JW
    ACKERMAN, JL
    LAUFFER, RB
    BUXTON, RB
    CHAO, YS
    WEDEEN, VJ
    BRADY, TJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1988, 6 (02) : 164 - 174
  • [10] WEINMANN HJ, 1989, ENHANCED MAGNETIC RE, P74