UV LASERS FOR FLOW CYTOMETRIC ANALYSIS - HECD VERSUS ARGON-LASER EXCITATION

被引:9
作者
GOLLER, B
KUBBIES, M
机构
[1] Dept. of Cell Biology, Boehringer Mannheim GmbH, 8122 Penzberg
关键词
FLOW CYTOMETRY; CELL KINETICS; CELL CYCLE; GLUTATHIONE; CALCIUM FLUX; HECD LASER; MONOCHLOROBIMANE; INDO-1; BRDU/HOECHST-PI; FLUOROCHROMES;
D O I
10.1177/40.4.1372632
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Applying flow cytometric single cell analysis, we compared the performance of UV excitation from argon ion and HeCd lasers using various UV-excitable fluorochromes of cell kinetic and cell physiological relevance. The AT-specific DNA fluorochromes DAPI, Hoechst 33258, and Hoechst 33342 showed no significant differences of G1-phase resolution and cell cycle distribution. With the HeCd laser, high-resolution cell kinetic analysis applying the novel BrdU/Hoechst-PI quenching technique showed superior resolution and an almost normalized G2M/G1 channel ratio of the first cell cycle. Indo-1 analysis for detection of intracellular free calcium gave similar results for both excitation sources, although the indo-1 ratio of activated cells was lower for HeCd excitation. Monochlorobimane as an indicator fluorochrome of glutathione content could not be excited sufficiently with the 325-nm line of the HeCd laser and exhibited poor resolution between positive and negative cells. However, the second glutathione-specific fluorochrome o-phtalaldehyde gave even better results with the HeCd laser. Our data indicate that air-cooled HeCd lasers are cheap and reliable UV-excitation sources for most UV-excitable fluorochromes, and might be an alternative to the expensive water-cooled argon and krypton laser.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 21 条
[1]   ANALYSIS AND SORTING OF LIVING CELLS ACCORDING TO DEOXYRIBONUCLEIC-ACID CONTENT [J].
ARNDTJOVIN, DJ ;
JOVIN, TM .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1977, 25 (07) :585-589
[2]   A COMPARISON OF LOW-POWER HELIUM-CADMIUM AND ARGON ULTRAVIOLET-LASERS IN COMMERCIAL FLOW CYTOMETERS [J].
BIGLER, RD .
CYTOMETRY, 1987, 8 (05) :441-444
[3]  
GRYNKIEWICZ G, 1985, J BIOL CHEM, V260, P3440
[4]   FLOW CYTOMETRIC MEASUREMENT OF CELLULAR IONIZED CALCIUM-CONCENTRATION [J].
JUNE, CH ;
RABINOVITCH, PS .
PATHOLOGY AND IMMUNOPATHOLOGY RESEARCH, 1988, 7 (05) :409-&
[5]   FLOW CYTOMETRIC ANALYSIS OF SMALL DNA CONTENT DIFFERENCES IN HETEROGENEOUS CELL-POPULATIONS - HUMAN AMNIOTIC-FLUID CELLS [J].
KOCH, H ;
BETTECKEN, T ;
KUBBIES, M ;
SALK, D ;
SMITH, JW ;
RABINOVITCH, PS .
CYTOMETRY, 1984, 5 (02) :118-123
[6]   CELL CYCLE-DEPENDENT DHFR AND T-PA PRODUCTION IN COTRANSFECTED, MTX-AMPLIFIED CHO CELLS REVEALED BY DUAL-LASER FLOW-CYTOMETRY [J].
KUBBIES, M ;
STOCKINGER, H .
EXPERIMENTAL CELL RESEARCH, 1990, 188 (02) :267-271
[7]   GLUTATHIONE RESTORES NORMAL-CELL ACTIVATION AND CELL-CYCLE PROGRESSION IN CISPLATINUM TREATED HUMAN-LYMPHOCYTES [J].
KUBBIES, M ;
GOLLER, B ;
SCHETTERS, B ;
BARTOSEK, I ;
ALBERT, W .
BRITISH JOURNAL OF CANCER, 1991, 64 (05) :843-849
[8]   COMPLEX CA-2+ FLUX INHIBITION AS PRIMARY MECHANISM OF STAUROSPORINE-INDUCED IMPAIRMENT OF T-CELL ACTIVATION [J].
KUBBIES, M ;
GOLLER, B ;
RUSSMANN, E ;
STOCKINGER, H ;
SCHEUER, W .
EUROPEAN JOURNAL OF IMMUNOLOGY, 1989, 19 (08) :1393-1398
[9]  
KUBBIES M, 1991, CYTOMETRY S, V5, P49
[10]  
KUBBIES M, 1989, FLOW CYTOMETRY ADV R, V2, P5