THE SIMULTANEOUS SPECIATION OF ALUMINUM AND IRON IN A FLOW-INJECTION SYSTEM

被引:36
作者
CLARKE, N [1 ]
DANIELSSON, LG [1 ]
机构
[1] ROYAL INST TECHNOL,DIV ANALYT CHEM,S-10044 STOCKHOLM,SWEDEN
关键词
KINETIC METHODS; FLOW INJECTION; ALUMINUM; IRON; SPECIATION; WATERS; OXINE; 1,10-ORTHOPHENANTHROLINE; MULTIVARIATE ANALYSIS; PARTIAL LEAST SQUARES;
D O I
10.1016/0003-2670(94)00674-B
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is possible to speciate Al and Fe simultaneously using complexation in a flow-injection system. Oxine is used as the reagent for Al and Fe(III), and 1,10-orthophenanthroline in combination with iodide as the reagent for Fe(II). The reaction products are extracted into chloroform. A diode array detector is used for measurement and a multivariate method, partial least squares, to separate the contributions to the signal from aluminium, iron(III) and iron(II). Results show that our system is able to measure the three components correctly in the presence of each other. The sampling frequency is 85 injections/h and the detection limit 0.06 mg/l for all three components. Results obtained with natural water samples were satisfactory. The only cation that might possibly interfere in normal samples is Ca2+. The 'free' ions, Al3+, Fe3+ and Fe2+, as well as some labile complexes, such as AlSO4+, are included in the measured parameter. Aluminium-fluoro complexes and large polymeric hydroxo complexes of Al and Fe(III) are excluded. Complexes with humic or fulvic acids are normally excluded, except in the case of Fe(III), for which they appear to be included to a small extent. The reduction of iron(III) to iron(II) and the oxidation of iron(II) to iron(III), in both cases mediated by humic substances, could be shown.
引用
收藏
页码:5 / 20
页数:16
相关论文
共 55 条
[1]  
[Anonymous], [No title captured]
[2]   POTENTIOMETRIC STUDY OF COMPLEXES OF MALONIC 5-SULPHOSALICYLIC AND CHROMOTROPIC ACIDS WITH SOME METAL IONS [J].
ATHAVALE, VT ;
MAHADEVA.N ;
MATHUR, PK ;
SATHE, RM .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1967, 29 (08) :1947-&
[3]   DESIGN AND EVALUATION OF A NEW PHASE SEPARATOR FOR LIQUID-LIQUID-EXTRACTION IN FLOW SYSTEMS [J].
BACKSTROM, K ;
DANIELSSON, LG ;
NORD, L .
ANALYTICA CHIMICA ACTA, 1985, 169 (MAR) :43-49
[5]  
BERGGREN D, 1995, UNPUB
[6]   ALUMINOSILICATE PHASES DURING INITIAL CLAY FORMATION - H+-AL-3+-OXALIC ACID SILICIC ACID-NA+ SYSTEM [J].
BILINSKI, H ;
HORVATH, L ;
INGRI, N ;
SJOBERG, S .
JOURNAL OF SOIL SCIENCE, 1990, 41 (01) :119-132
[7]   DIODE-ARRAY DETECTORS IN FLOW-INJECTION ANALYSIS - MIXTURE RESOLUTION BY MULTI-WAVELENGTH ANALYSIS [J].
BLANCO, M ;
GENE, J ;
ITURRIAGA, H ;
MASPOCH, S ;
RIBA, J .
TALANTA, 1987, 34 (12) :987-993
[8]   SOLUBLE ALUMINUM SILICATES - STOICHIOMETRY, STABILITY, AND IMPLICATIONS FOR ENVIRONMENTAL GEOCHEMISTRY [J].
BROWNE, BA ;
DRISCOLL, CT .
SCIENCE, 1992, 256 (5064) :1667-1670
[9]   ON THE INFLUENCE OF CARBONATE IN MINERAL DISSOLUTION .1. THE THERMODYNAMICS AND KINETICS OF HEMATITE DISSOLUTION IN BICARBONATE SOLUTIONS AT T = 25-DEGREES-C [J].
BRUNO, J ;
STUMM, W ;
WERSIN, P ;
BRANDBERG, F .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1992, 56 (03) :1139-1147
[10]   ON THE INFLUENCE OF CARBONATE IN MINERAL DISSOLUTION .2. THE SOLUBILITY OF FECO3 (S) AT 25-DEGREES-C AND 1 ATM TOTAL PRESSURE [J].
BRUNO, J ;
WERSIN, P ;
STUMM, W .
GEOCHIMICA ET COSMOCHIMICA ACTA, 1992, 56 (03) :1149-1155