AUTOMATED SAMPLE CLEANUP WITH SOLID-PHASE EXTRACTION FOR THE DETERMINATION OF AFLATOXINS IN URINE BY LIQUID-CHROMATOGRAPHY

被引:21
作者
KUSSAK, A [1 ]
ANDERSSON, B [1 ]
ANDERSSON, K [1 ]
机构
[1] NATL INST OCCUPAT HLTH,DIV ANALYT CHEM,POB 7654,S-90713 UMEA,SWEDEN
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1993年 / 616卷 / 02期
关键词
D O I
10.1016/0378-4347(93)80391-G
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated extraction and clean-up procedure was developed for the determination of aflatoxins in human urine at the 50 Pg/ml level. Aflatoxins B1, B2, G1 and G2 are captured on C2 extraction columns and simultaneously cleaned up with the aid of a robotic system. The processed samples are analysed by reversed-phase high-performance liquid chromatography. Fluorescence detection was enhanced for aflatoxins B1 and G1 using factorial design optimization of the post-column reactor. Silylation of the glass vials used in the robotic system was of the utmost importance. With non-silylated glass vials, up to 75% of the analytes were lost. Average aflatoxin recoveries were B1 95% B2 90%, G1 93% and G2 89%.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 22 条
[1]   EXPOSURE TO AFLATOXINS IN DENMARK [J].
AUTRUP, H .
JOURNAL OF TOXICOLOGY-TOXIN REVIEWS, 1989, 8 (1-2) :53-67
[2]   AFLATOXIN METABOLITES IN THE URINE OF NIGERIANS COMPARISON OF CHROMATOGRAPHIC METHODS [J].
BEAN, TA ;
YOURTEE, DM ;
AKANDE, B ;
OGUNLEWE, J .
JOURNAL OF TOXICOLOGY-TOXIN REVIEWS, 1989, 8 (1-2) :43-52
[3]  
BETINA V, 1989, MYCOTOXINS BIOACTIVE, V9
[4]  
CARLSON R, 1992, DESIGN OPTIMIZATION
[5]   SUBSTANCES WITH AFFINITY TO A MONOCLONAL AFLATOXIN-B1 ANTIBODY IN DANISH URINE SAMPLES [J].
DRAGSTED, LO ;
BULL, I ;
AUTRUP, H .
FOOD AND CHEMICAL TOXICOLOGY, 1988, 26 (03) :233-242
[6]  
Dvorackova I., 1990, AFLATOXINS HUMAN HLT
[7]   DETERMINATION OF AFLATOXIN-M1 USING A DIALYSIS-BASED IMMUNOAFFINITY SAMPLE PRETREATMENT SYSTEM COUPLED ONLINE TO LIQUID-CHROMATOGRAPHY - REUSABLE IMMUNOAFFINITY COLUMNS [J].
FARJAM, A ;
VANDEMERBEL, NC ;
NIEMAN, AA ;
LINGEMAN, H ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY, 1992, 589 (1-2) :141-149
[8]   DETERMINATION OF AFLATOXINS IN PEANUT PRODUCTS USING DISPOSABLE BONDED-PHASE COLUMNS AND POSTCOLUMN REACTION DETECTION [J].
HURST, WJ ;
SNYDER, KP ;
MARTIN, RA .
JOURNAL OF CHROMATOGRAPHY, 1987, 409 :413-418
[9]   PRIMARY LIVER-CANCER AND OCCUPATIONAL EXPOSURE [J].
KAUPPINEN, T ;
RIALA, R ;
SEITSAMO, J ;
HERNBERG, S .
SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1992, 18 (01) :18-25
[10]  
KOELTZOW DE, 1990, J ASSOC OFF ANA CHEM, V73, P584