DETERMINATION OF GENTAMICIN PHARMACOKINETICS BY BIOELECTRICAL-IMPEDANCE IN CRITICALLY ILL ADULTS

被引:9
作者
ZAROWITZ, BJ
ROBERT, S
MLYNAREK, M
PETERSON, EL
HORST, HM
机构
[1] WAYNE STATE UNIV, DEPT PHARM PRACTICE, DETROIT, MI 48202 USA
[2] UNIV MONTREAL, DEPT CLIN PHARM, MONTREAL H3C 3J7, QUEBEC, CANADA
[3] HOP HOTEL DIEU, CTR RECH, MONTREAL H2W 1T8, QUEBEC, CANADA
[4] HENRY FORD HOSP, DIV BIOSTAT & EPIDEMIOL, DETROIT, MI 48202 USA
关键词
D O I
10.1002/j.1552-4604.1993.tb04704.x
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
This investigation compares the accuracy of calculating gentamicin pharmacokinetic parameters by a noninvasive body composition technique (bioelectrical impedance analysis; BIA) with an empiric method, against the two-point method as the criterion standard. A prospective concurrent open label design was used. The 32 medical and surgical intensive care unit beds at Henry Ford Hospital, a not-for-profit, university-affiliated teaching hospital, served as the setting. Twenty critically ill adults, Therapeutic Index Scoring System (TISS) = 4, who required gentamicin as part of their normal course of therapy for gram-negative bacillary infections, were evaluated. Gentamicin V(d) and k were calculated by three methods. After measurement of body composition parameters by BIA, previously derived gentamicin dosing equations were used to predict gentamicin volume of distribution (V(d)) and elimination rate constant (k) (BIA method). Empiric estimates of these parameters (V(d) = 0.3L/kg and k derived from creatinine clearance) were compared with the BIA parameters against a criterion standard V(d) and k determined from a two-point sampling of gentamicin serum concentrations. Measurements of BIA parameters and gentamicin serum concentrations were made in duplicate with coefficients of variation, less-than-or-equal-to 2% and less-than-or-equal-to 3%, respectively. The BIA and empiric methods produced resultant pharmacokinetic parameters (V(d) and k) not different than those measured by the two-point method. There were no statistically significant differences in mean error (bias), or mean squared error (precision) for both V(d) and k assessed by the empiric or BIA methods. In this sample of critically ill adults there is no apparent advantage of BIA-derived predictive pharmacokinetic equations over an empiric method of predicting gentamicin V(d) and k. Further study with variable frequency BIA technology is needed to assess BIA applications in the critically ill.
引用
收藏
页码:562 / 567
页数:6
相关论文
共 30 条
[1]   ELECTRICAL-IMPEDANCE IN ASSESSING HUMAN-BODY COMPOSITION - THE BIA METHOD [J].
ABUKHALED, M ;
MCCUTCHEON, MJ ;
REDDY, S ;
PEARMAN, PL ;
HUNTER, GR ;
WEINSIER, RL .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1988, 47 (05) :789-792
[2]  
ACKMANN JJ, 1984, CRIT REV BIOMED ENG, V11, P281
[3]  
BOYCE EG, 1989, CLIN PHARMACY, V8, P48
[4]  
COBB M, 1982, AM J MED TECHNOL, V48, P671
[5]  
COCHRAN WG, 1967, SAMPLING TECHNIQUES, P154
[6]   PREDICTION OF CREATININE CLEARANCE FROM SERUM CREATININE [J].
COCKCROFT, DW ;
GAULT, MH .
NEPHRON, 1976, 16 (01) :31-41
[7]  
COSELMAN CL, 1992, CLIN PHARMACOL THER, V51, P158
[8]   VARIABILITY IN AMINOGLYCOSIDE PHARMACOKINETICS IN CRITICALLY ILL SURGICAL PATIENTS [J].
DASTA, JF ;
ARMSTRONG, DK .
CRITICAL CARE MEDICINE, 1988, 16 (04) :327-330
[9]  
FUHS DW, 1988, CLIN PHARMACY, V7, P207
[10]  
JAMESON JP, 1991, DICP ANN PHARMAC, V25, P635