STABILITY INCREASE OF THE LUMBAR SPINE WITH DIFFERENT MUSCLE GROUPS - A BIOMECHANICAL IN-VITRO STUDY

被引:407
作者
WILKE, HJ
WOLF, S
CLAES, LE
ARAND, M
WIESEND, A
机构
[1] Abteilung fur Unfallchirurgische Forschung und Biomechanik, Universitat Ulm, Ulm
[2] Abteilung fur Unfallchirurgie, Hand- Plastische- und Wiederherstellungschirurgie, Chirurgische Universitatsklinik, Ulm
关键词
Biomechcnics; Mechanical tasting; Muse la simulation; Spina tester; Spinal stability;
D O I
10.1097/00007632-199501150-00011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. This study investigated the influence of five different muscle groups on the monosegmental motion (L4-L5) during pure flexion/extension, lateral bending, and axial rotation moments. Objectives. The results showed and compared the effect of different muscle groups acting in different directions on the stability of a single motion segment to find loading conditions for in vitro experiments that simulate more physiologically reasonable loads. Summary of Background Data. In spine biomechanics research, most in vitro experiments have been carried out without applying muscle forces, even though these forces stabilize the spinal column in vivo. Methods. Seven human lumbosacral spines were tested in a spine tester that allows simulation of up to five symmetrical muscle forces. Changing pure flexion/extension, lateral bending, and axial rotation moments up to +/-3.75 Nm were applied without muscle forces, with different muscle groups and combinations. The three-dimensional monosegmental motion was determined using an instrumented spatial linkage system. Results. Simulated muscle forces were found to strongly influence load-deformation characteristics. Muscle action generally decreased the range of motion and the neutral zone of the motion segments. This was most evident for flexion and extension. After five pairs of symmetrical, constant muscle forces were applied (80 N per pair), the range of motion decreased about 93% in flexion and 85% in extension. The total neutral zone for flexion and extension was decreased by 83% muscle action. The multifidus muscle group had the strongest influence. Conclusion. This experiment showed the importance of including at least some of the most important muscle groups in in vitro experiments on lumbar spine specimens.
引用
收藏
页码:192 / 198
页数:7
相关论文
共 27 条
  • [1] Adams M.A., Dolan P., A technique for quantifying the bending moment acting on the lumbar spine in vivo, Spine, 24, pp. 117-126, (1991)
  • [2] Adams M.A., McNally, Wagstaff J, Goodship AE. Abnormal stress concentrations in lumbar intervertebral discs following damage to vertebral bodies: A cause of disc failure, European Spine Journal, 1, pp. 214-221, (1993)
  • [3] Bergmark A., Stability of the lumbar spine, Acta Orthop Scand (Suppl), 230, pp. 20-24, (1989)
  • [4] Bogduk N., Macintosh J.E., Pearcy M.J., A universal model of the lumbar back muscles in the upright position, Spine, 17, pp. 897-913, (1992)
  • [5] Bogduk N., Twomey L.T., Clinical Anatomy of the Lumbar Spine, (1987)
  • [6] Crisco J.J., Panjabi M.M., The intersegmental and multiseg- mental muscles of the lumbar spine. A biomechanical model comparing lateral stabilizing potential, Spine, 16, pp. 793-799, (1991)
  • [7] Eggli S., Schlapfer F., Angst M., Witschger P., Aebi M., Bio¬mechanical testing of three newly developed transpedicular multisegmental fixation systems, European Spine Journal, 1, pp. 109-116, (1992)
  • [8] El-Bohy A.A., Yang K., King Al. Experimental verification of facet load transmission by direct measurements of facet lamina contact pressure, J Biomech, 22, pp. 931-941, (1989)
  • [9] Goel V.K., Kong W., Han Jung S., Weinstein J.N., Gilbertson L.G., A combined finite element and optimization investigation of lumbar spine mechanics with and without muscles, Spine, 18, pp. 1531-1541, (1993)
  • [10] Goel V.K., Goyal S., Clark C., Nishiyama K., Kinematics of the whole lumbar spine, Spine, 10, pp. 543-554, (1985)