The Potentiometric Performance of Mercury (II) Ion-Selective Electrode Based on Tetracycline Antibiotics

被引:2
作者
Baek, Jonggyu [2 ]
Paeng, Insook Rhee [1 ]
机构
[1] Seoul Womens Univ, Dept Chem, Seoul 139774, South Korea
[2] Yonsei Univ, Dept Chem, Wonju 220710, South Korea
来源
JOURNAL OF THE KOREAN ELECTROCHEMICAL SOCIETY | 2008年 / 11卷 / 01期
关键词
Tetracycline; Antibiotics; Mercury (II) ion; Ion-selective electrode;
D O I
10.5229/JKES.2008.11.1.059
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Poly (vinylchloride) (PVC) membrane electrodes based on neutral carrier, tetracycline was prepared as an active sensor for Hg(II) ion, and tested in different contents of the potassium tetrakis (4-chlorophenyl) borate (KTpC1PB) as lipophilic salt. Bis (2-ethylhexyl) sebacate (DOS), bis(1-butylpentyl) adipate (BBPA), 2-nitrophenyl octyl ether (NPOE) and dibutyl phthalate (DBP) were used as diverse plasticizing solvent mediators. This electrode shows excellent potentiometric response characteristics and display good linearity with log [Hg2+] versus EMF response, over a range of concentrations between 10(-7) and 10(-3) M. With 30.8 mV/decade Nemstian slope, the detection limit was 6.9 x 10(-9) M and the response time was less than 20s. The proposed electrode yields very good selectivity for mercury (II) ion over many cations such as alkali, alkaline earth, transition and heavy metal ions. And it shows a very stable potential values in a wide pH range. This reliable electrode prepared was kept at least a month without considerable alteration in their response to Hg (II) ion.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 25 条
[1]   AVIDITY OF TERRAMYCIN AND AUREOMYCIN FOR METALLIC CATIONS [J].
ALBERT, A .
NATURE, 1953, 172 (4370) :201-201
[2]   AVIDITY OF THE TETRACYCLINES FOR THE CATIONS OF METALS [J].
ALBERT, A ;
REES, CW .
NATURE, 1956, 177 (4505) :433-434
[3]  
Baek J, 2008, B KOREAN CHEM SOC, V29, P165
[4]   METAL BINDING IN TETRACYCLINES . COBALT(2) AND NICKEL(2) COMPLEXES [J].
BAKER, WA ;
BROWN, PM .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1966, 88 (06) :1314-&
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   THERMODYNAMICS OF CHELATION BY TETRACYCLINES [J].
BENET, LZ ;
GOYAN, JE .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1966, 55 (11) :1184-&
[7]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[8]   SELECTIVITY OF CATION CHELATION TO TETRACYCLINES - EVIDENCE FOR SPECIAL CONFORMATION OF CALCIUM CHELATE [J].
CASWELL, AH ;
HUTCHISON, JD .
BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 1971, 43 (03) :625-+
[9]   BIOPHYSICAL STUDY OF MODE OF ACTION OF TETRACYCLINE ANTIBIOTICS - INHIBITION OF METALLOFLAVOENZYME NADH CYTOCHROME OXIDOREDUCTASE [J].
COLAIZZI, JL ;
KNEVEL, AM ;
MARTIN, AN .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1965, 54 (10) :1425-&
[10]   METAL COMPLEXATION OF TETRACYCLINE HYDROCHLORIDES [J].
DOLUISIO, JT ;
MARTIN, AN .
JOURNAL OF MEDICINAL CHEMISTRY, 1963, 6 (01) :16-&