FACTORS AFFECTING ACCURACY AND PRECISION IN PET VOLUME IMAGING

被引:12
作者
KARP, JS [1 ]
DAUBEWITHERSPOON, ME [1 ]
MUEHLLEHNER, G [1 ]
机构
[1] NIH,DEPT NUCL MED,BETHESDA,MD 20892
关键词
POSITRON EMISSION TOMOGRAPHY; VOLUME IMAGING; AXIAL SAMPLING; SPATIAL RESOLUTION; SCATTERED RADIATION;
D O I
10.1038/jcbfm.1991.35
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Volume imaging positron emission tomographic (PET) scanners with no septa and a large axial acceptance angle offer several advantages over multiring PET scanners. A volume imaging scanner combines high sensitivity with fine axial sampling and spatial resolution. The fine axial sampling minimizes the partial volume effect, which affects the measured concentration of an object. Even if the size of an object is large compared to the slice spacing in a multiring scanner, significant variation in the concentration is measured as a function of the axial position of the object. With a volume imaging scanner, it is necessary to use a three-dimensional reconstruction algorithm in order to avoid variations in the axial resolution as a function of the distance from the center of the scanner. In addition, good energy resolution is needed in order to use a high energy threshold to reduce the coincident scattered radiation.
引用
收藏
页码:A38 / A44
页数:7
相关论文
共 12 条
[1]   DESIGN CONSIDERATIONS FOR POSITRON EMISSION TOMOGRAPHY [J].
BROOKS, RA ;
SANK, VJ ;
FRIAUF, WS ;
LEIGHTON, SB ;
CASCIO, HE ;
DICHIRO, G .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) :158-177
[2]   CYLINDRICAL PET DETECTOR DESIGN [J].
BURNHAM, CA ;
KAUFMAN, DE ;
CHESLER, DA ;
STEARNS, CW ;
WOLFSON, DR ;
BROWNELL, GL .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1988, 35 (01) :675-679
[3]   SPHERICAL POSITRON EMISSION TOMOGRAPH (S-PET) I - PERFORMANCE ANALYSIS [J].
CHO, ZH ;
HONG, KS ;
HILAL, SK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (02) :422-438
[4]  
DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
[5]   AN ITERATIVE IMAGE SPACE RECONSTRUCTION ALGORITHM SUITABLE FOR VOLUME ECT [J].
DAUBEWITHERSPOON, ME ;
MUEHLLEHNER, G .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (02) :61-66
[6]   EVALUATING THE PERFORMANCE OF MULTIPLANE POSITRON TOMOGRAPHS DESIGNED FOR BRAIN IMAGING [J].
HOFFMAN, EJ ;
PHELPS, ME ;
HUANG, SC ;
PLUMMER, D ;
KUHL, DE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) :469-473
[7]  
KARP JS, 1990, IN PRESS J NUCL MED
[8]   THE HIGH COUNT RATE PERFORMANCE OF A 2-DIMENSIONALLY POSITION-SENSITIVE DETECTOR FOR POSITRON EMISSION TOMOGRAPHY [J].
MANKOFF, DA ;
MUEHLLEHNER, G ;
KARP, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (04) :437-456
[9]   THE THEORY OF 3-DIMENSIONAL IMAGE-RECONSTRUCTION FOR PET [J].
ROGERS, JG ;
HARROP, R ;
KINAHAN, PE .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1987, 6 (03) :239-243
[10]  
STEARNS C, 1988, IEEE T NUCL SCI, V35, P703