THE [C-14] TRIOLEIN BREATH TEST IS NOT VALID AS A TEST OF FAT-ABSORPTION

被引:11
作者
PEDERSEN, NT
JORGENSEN, BB
RANNEM, T
机构
[1] GLOSTRUP CTY HOSP, DEPT MED F, DK-2600 GLOSTRUP, DENMARK
[2] UNIV COPENHAGEN, RIGSHOSP, MED DEPT A, DIV GASTROENTEROL, DK-2100 COPENHAGEN, DENMARK
关键词
BREATH TEST; CARBON ISOTOPES; MALABSORPTION;
D O I
10.3109/00365519109104583
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The [C-14]-triolein breath test is used as a test of fat absorption. However, its validity has not been established. The aim of this study was to investigate, whether the absorption of [C-14]-triolein could be estimated from the breath test, and whether the breath test could be useful as a clinical test. The [C-14]-triolein absorption was estimated from faecal measurements, using (CrCl3)-Cr-51 as non-absorbable marker. The breath test was done according to the standard technique with hourly estimations of the (CO2)-C-14 expiration. Fifty-one patients participated. A nearly perpendicular, curvilinear relation between the 6-h cumulative (CO2)-C-14 expiration and the [C-14]-triolein absorption was found, and no obvious cut-off level for normal (CO2)-C-14 expiration could be identified. Accordingly, the diagnostic sensitivity of the breath test was 80% at the expense of a specificity of 45%. In 19 patients duplicate measurements were done. A high intra- and inter-individual variation in the fraction of absorbed [C-14]-triolein, expired within 6 h, was found. It is concluded that expiration of (CO2)-C-14 is influenced by factors other than the absorption of [C-14]-triolein, and that the [C-14]-triolein breath test is not useful as test of fat absorption.
引用
收藏
页码:699 / 703
页数:5
相关论文
共 14 条
[1]   IS THE C-14 TRIOLEIN BREATH TEST USEFUL IN THE ASSESSMENT OF MALABSORPTION IN CLINICAL-PRACTICE [J].
BENINI, L ;
SCURO, LA ;
MENINI, E ;
MANFRINI, C ;
VANTINI, I ;
VAONA, B ;
BROCCO, G ;
TALAMINI, G ;
CAVALLINI, G .
DIGESTION, 1984, 29 (02) :91-97
[2]   C-14 TRIOLEIN BREATH TEST AS A RAPID AND CONVENIENT SCREENING-TEST FOR FAT MALABSORPTION [J].
EINARSSON, K ;
BJORKHEM, I ;
EKLOF, R ;
BLOMSTRAND, R .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1983, 18 (01) :9-12
[3]  
GOFF JS, 1982, GASTROENTEROLOGY, V83, P44
[4]  
KING CE, 1981, J NUCL MED, V22, P955
[5]  
MILLS PR, 1979, SCAND J GASTROENTERO, V14, P913
[6]   C-14 TRIOLEIN BREATH TEST - A ROUTINE TEST IN THE GASTROENTEROLOGY CLINIC [J].
MYLVAGANAM, K ;
HUDSON, PR ;
ROSS, A ;
WILLIAMS, CP .
GUT, 1986, 27 (11) :1347-1352
[7]   C-14 TRIOLEIN BREATH TEST - AN ASSESSMENT IN THE ELDERLY [J].
MYLVAGANAM, K ;
HUDSON, PR ;
HERRING, A ;
WILLIAMS, CP .
GUT, 1989, 30 (08) :1082-1086
[8]  
NEWCOMER AD, 1979, GASTROENTEROLOGY, V76, P6
[9]   FECAL FAT AND FECAL WEIGHT - REPRODUCIBILITY AND DIAGNOSTIC EFFICIENCY OF VARIOUS REGIMENS [J].
PEDERSEN, NT ;
HALGREEN, H .
SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1984, 19 (03) :350-354
[10]  
PEDERSEN NT, 1981, EUR J NUCL MED, V6, P327