THE RELIABILITY OF NONINVASIVE CONTINUOUS FINGER BLOOD-PRESSURE MEASUREMENT IN PATIENTS WITH BOTH HYPERTENSION AND VASCULAR-DISEASE

被引:87
作者
BOS, WJW [1 ]
IMHOLZ, BPM [1 ]
VANGOUDOEVER, J [1 ]
WESSELING, KH [1 ]
VANMONTFRANS, GA [1 ]
机构
[1] UNIV AMSTERDAM,DEPT INTERNAL MED,AMSTERDAM,NETHERLANDS
关键词
CONTINUOUS FINGER BLOOD PRESSURE; BLOOD PRESSURE DETERMINATION; COMPARISON; STANDING UP; VALSALVA MANEUVER; HYPERTENSION; VASCULAR DISEASE;
D O I
10.1093/ajh/5.8.529
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
In conditions of compromised peripheral circulation, the measurement of noninvasive continuous finger blood pressure with the Finapres device may show reduced accuracy. We therefore compared Finapres blood pressure (FINAP) with intrabrachial blood pressure (IAP) responses to the Valsalva maneuver and arising in 12 patients in whom the peripheral circulation was expected to be compromised due to the combination of therapy-resistant hypertension and vascular disease. During a 30 sec control period the FINAP - IAP differences were - 15.7 +/- 18.8 mm Hg (mean +/- SD) for systolic, - 20.1 +/- 15.7 mm Hg for mean, and - 13.5 +/- 15.7 mm Hg for diastolic pressure. During the Valsalva maneuver and prolonged standing Finapres reproduced the essential characteristics of the changes in IAP in all patients. However, in individual patients, the magnitude of the intraarterial blood pressure response was sometimes over- or underestimated by Finapres. Nevertheless, the group averaged blood pressure, in particular mean and diastolic pressure, response to cardiovascular stimuli, was well reproduced by Finapres. In conclusion, as expected physiologically, individual Finapres measurements in patients with vascular disease do not always equal the intrabrachial pressure and should thus be evaluated with care. However, the Finapres device can be used with sufficient confidence to study the group averaged responses to cardiovascular stimuli in these patients.
引用
收藏
页码:529 / 535
页数:7
相关论文
共 33 条
  • [1] Wesseling K.H., Finapres, continuous noninvasive finger arterial pressure based on the method of Penaz, Blood Pressure Measurement, pp. 161-172, (1990)
  • [2] Wesseling K.H., Settels J.J., Van Der Hoeven G., Et al., Effects of peripheral vaso-constriction on the measurement of blood pressure in a finger, Cardiovasc Res, 19, pp. 139-145, (1985)
  • [3] Imholz B., Van Montfrans G.A., Settels J.J., Et al., Continuous noninvasive blood pressure monitoring
  • [4] reliability of Finapres device during the Valsalva manoeuvre, Cardiovasc Res, 22, pp. 390-397, (1988)
  • [5] Imholz B., Settels J.J., Van Der Meiracker A.H., Et al., Non-invasive continuous finger blood pressure measurement during orthostatic stress compared to intra-arterial pressure, Cardiovasc Res, 24, pp. 214-221, (1990)
  • [6] Parati G., Casadei R., Gropelli A., Et al., Comparison of finger and intraarterial blood pressure monitoring in rest and during laboratory tests, Hypertension, 13, pp. 647-655, (1989)
  • [7] Gorback M.S., Quill T.J., La Vine M.L., The relative accuracies of two automated noninvasive arterial pressure measurement devices, J Clin Monit, 7, pp. 13-22, (1991)
  • [8] Wieling W., Ten Harkel A., Van Lieshout J.J., Spectrum of orthostatic disorders: Classification based on an analysis Of the short-term circulatory response upon standing, Clin Sci, 81, pp. 241-248, (1991)
  • [9] Imholz B., Wieling W., Langewouters G.J., Van Montfrans G.A., Continuous finger arterial pressure: Utility in the cardiovascular laboratory, Clinical Autonomic Research, 1, pp. 43-53, (1991)
  • [10] Takahashi H., Yoshimura M., Nishimura M., Et al., Measurement of digital arterial pressure in patients with essential hypertension, Jpn Circ J, 54, pp. 221-230, (1990)