OPAQUE CONTACT-LENSES FOR YAG LASER IRIDOTOMY OCCLUSION

被引:7
作者
FRESCO, BB
TROPE, GR
机构
[1] Toronto, ON
[2] University of Toronto, Toronto, ON
关键词
YAG LASER; IRIDOTOMY; ANGLE-CLOSURE GLAUCOMA; GLARE EFFECTS; OPAQUE CONTACT LENSES;
D O I
10.1097/00006324-199208000-00010
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Although a laser-produced iridotomy effectively controls angle-closure glaucoma the iridotomy can cause annoying visual effects. One solution is to fit a toric contact lens with an opaque portion to cover the iridotomy.
引用
收藏
页码:656 / 657
页数:2
相关论文
共 7 条
[1]
Fleck B.W., How large must an Irldotomy be?, Br J Ophthalmol, 74, pp. 583-588, (1990)
[2]
Beicher C.D., Laser iridotomy, Photocoagulation in Glaucoma and Anterior Segment Disease, pp. 87-110, (1984)
[3]
Hirst L.W., Robin A.L., Sherman S., Green W.R., D'Anna S., Dunkelberger G., Corneal endothelial changes after argon-laser iridotomy and panretinal photocoagulation, Am J Ophthalmol, 93, pp. 473-481, (1982)
[4]
Corriveau L.A., Nasr Y., Fanous S., Choroidal and retinal detachment following argon laser iridotomy, Can J Ophthalmol, 21, pp. 107-108, (1986)
[5]
Karjalainen G., Laatlkainen L., Raitta C., Bilateral nonrhegma-togenous retinal detachment following Neodymium-YAG laser iridotomies, Arch Ophthalmol, 104, (1986)
[6]
Phillips R.C., Campbell M., Flanagan J.G., Trope G.E., Optical explanation of visual blur with partially exposed iridotomies, Invest Ophthalmol Vis Sei, (1991)
[7]
Murphy P.H., Trope G.E., Monocular blurring: A complication of YAG laser iridotomy, Ophthalmology (Rochester), 98, pp. 1539-1542, (1991)