HIGH-CURRENT HOLLOW-CATHODE SOURCE AS A RADIANT INTENSITY STANDARD IN THE 40-125-NM WAVELENGTH RANGE

被引:39
作者
HOLLANDT, J
KUHNE, M
WENDE, B
机构
[1] Physikalisch-Technische Bundesanstalt, Berlin, D-10587
来源
APPLIED OPTICS | 1994年 / 33卷 / 01期
关键词
SOURCES; RADIOMETRY; VACUUM ULTRAVIOLET;
D O I
10.1364/AO.33.000068
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The radiant intensity of VUV emission lines of a high-current hollow-cathode source has been determined for the 40-125-nm spectral range. The source is operated at a constant current of 1 A with an aluminum cathode. Different rare gases are alternatively used as the buffer gas at pressures of similar to 100 Pa. The radiant intensity has been determined by comparison with the calculable spectral radiant flux of the electron storage ring BESSY. Radiant intensities of the emission lines are in the 7-1400-mu W/sr range. The long-term reproducibility of the radiant intensity of the source is within +/-10% (2 sigma value). The systematic uncertainty of the radiometric calibration is better than 9% (root 3 sigma value).
引用
收藏
页码:68 / 74
页数:7
相关论文
共 15 条
[1]   ELECTRON STORAGE RING BESSY AS A SOURCE OF CALCULABLE SPECTRAL PHOTON FLUX IN THE X-RAY REGION [J].
ARNOLD, D ;
ULM, G .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1539-1542
[2]   A HIGH-CURRENT HOLLOW-CATHODE AS A SOURCE OF INTENSE LINE RADIATION IN THE VUV [J].
DANZMANN, K ;
FISCHER, J ;
KUHNE, M .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1985, 18 (07) :1299-1305
[3]   HIGH-CURRENT HOLLOW-CATHODE AS A RADIOMETRIC TRANSFER STANDARD SOURCE FOR THE EXTREME VACUUM ULTRAVIOLET [J].
DANZMANN, K ;
GUNTHER, M ;
FISCHER, J ;
KOCK, M ;
KUHNE, M .
APPLIED OPTICS, 1988, 27 (23) :4947-4951
[4]   SPECTRAL RADIANT POWER MEASUREMENTS OF VUV AND SOFT-X-RAY SOURCES USING THE ELECTRON STORAGE RING BESSY AS A RADIOMETRIC STANDARD SOURCE [J].
FISCHER, J ;
KUHNE, M ;
WENDE, B .
APPLIED OPTICS, 1984, 23 (23) :4252-4260
[5]   LASER-PRODUCED PLASMAS AS RADIOMETRIC TRANSFER-STANDARD SOURCES FOR THE VACUUM ULTRAVIOLET AND THE SOFT-X-RAY RANGE [J].
FISCHER, J ;
KUHNE, M ;
WENDE, B .
METROLOGIA, 1987, 23 (04) :179-186
[6]   A BEAM LINE FOR RADIANT POWER MEASUREMENTS OF VACUUM ULTRAVIOLET AND ULTRAVIOLET SOURCES IN THE WAVELENGTH RANGE 40-400-NM [J].
HOLLANDT, J ;
JANS, W ;
KUHNE, M ;
LINDENLAUF, F ;
WENDE, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1278-1281
[7]  
HOLLANDT J, 1992, ESA B, V69, P78
[8]  
JANS W, 1993, THESIS TU BERLIN
[9]  
KUHNE M, 1982, APPL OPTICS, V21, P3919, DOI 10.1364/AO.21.003919
[10]   VACUUM UV AND SOFT-X-RAY RADIOMETRY [J].
KUHNE, M ;
WENDE, B .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (08) :637-647