MULTIPARAMETER OPTIMIZATIONS IN MICELLAR LIQUID-CHROMATOGRAPHY USING THE ITERATIVE REGRESSION OPTIMIZATION STRATEGY

被引:40
作者
STRASTERS, JK [1 ]
KIM, ST [1 ]
KHALEDI, MG [1 ]
机构
[1] N CAROLINA STATE UNIV,DEPT CHEM,POB 8204,RALEIGH,NC 27695
来源
JOURNAL OF CHROMATOGRAPHY | 1991年 / 586卷 / 02期
关键词
D O I
10.1016/0021-9673(91)85126-Z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An extension of the iterative regression optimization strategy to multi-parameter optimizations is described and applied to the separation of ionic compounds (amino acids and peptides) by means of micellar liquid chromatography. The parameters examined are the concentration of surfactant, the concentration of 2-propanol and pH. Fairly regular (linear, weakly curved) retention behaviour of the compounds as a function of the parameters results in an efficient optimization using a relatively small number of initial experiments.
引用
收藏
页码:221 / 232
页数:12
相关论文
共 25 条
[1]   PARTITIONING BEHAVIOR OF SOLUTES ELUTED WITH MICELLAR MOBILE PHASES IN LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
NOME, F .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1662-1666
[2]   MODEL FOR MICELLAR EFFECTS ON LIQUID-CHROMATOGRAPHY CAPACITY FACTORS AND FOR DETERMINATION OF MICELLE SOLUTE EQUILIBRIUM-CONSTANTS [J].
ARUNYANART, M ;
LOVE, LJC .
ANALYTICAL CHEMISTRY, 1984, 56 (09) :1557-1561
[3]   RATIONALIZATION OF THE SELECTION OF THE TYPE OF THE ORGANIC MODIFIER(S) FOR SELECTIVITY OPTIMIZATION IN REVERSED-PHASE ION-PAIR CHROMATOGRAPHY [J].
BARTHA, A ;
VIGH, G ;
STAHLBERG, J .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :403-419
[4]  
Berridge JC., 1985, TECHNIQUES AUTOMATED
[5]   SELECTION OF MOBILE PHASE PARAMETERS AND THEIR OPTIMIZATION IN REVERSED-PHASE LIQUID-CHROMATOGRAPHY [J].
BILLIET, HAH ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :27-50
[6]   SIMULTANEOUS-OPTIMIZATION OF REAGENT CONCENTRATION AND PH IN REVERSED-PHASE ION-PAIRING CHROMATOGRAPHY [J].
BILLIET, HAH ;
VUIK, J ;
STRASTERS, JK ;
DEGALAN, L .
JOURNAL OF CHROMATOGRAPHY, 1987, 384 :153-162
[7]   APPLICATION OF A MIXTURE DESIGN TECHNIQUE TO THE SIMULTANEOUS-OPTIMIZATION OF ANALYSIS TIME AND RESOLUTION IN REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY USING A MINIMAL RESOLUTION PLOT [J].
COENEGRACHT, PMJ ;
VANTUYEN, N ;
METTING, HJ ;
COENEGRACHTLAMERS, PJM .
JOURNAL OF CHROMATOGRAPHY, 1987, 389 (02) :351-367
[8]   COMPARISON OF OPTIMIZATION METHODS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING MIXTURE DESIGNS AND MULTICRITERIA DECISION-MAKING [J].
COENEGRACHT, PMJ ;
SMILDE, AK ;
METTING, HJ ;
DOORNBOS, DA .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :195-217
[9]   EFFICIENCY ENHANCEMENT IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
DORSEY, JG ;
DEECHEGARAY, MT ;
LANDY, JS .
ANALYTICAL CHEMISTRY, 1983, 55 (06) :924-928
[10]  
DROUEN ACJ, 1985, THESIS DELFT U TECHN