COMPARISON OF MOUSE AND RABBIT LUNG DAMAGE EXPOSURE TO 30 KHZ ULTRASOUND

被引:16
作者
OBRIEN, WD [1 ]
ZACHARY, JF [1 ]
机构
[1] UNIV ILLINOIS,DEPT VET PATHOBIOL,URBANA,IL 61801
关键词
MOUSE; RABBIT; LUNG; ULTRASOUND; SPECIES COMPARISON; HEMORRHAGE; DAMAGE; BIOEFFECT; LESION;
D O I
10.1016/0301-5629(94)90070-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Twenty-four mice and sixteen rabbits were evaluated at one exposure duration (10 min) and at three exposure acoustic pressure levels (0, 100 and 145 kPa) at an ultrasonic frequency of 30 kHz, continuous wave for the purpose of testing whether there was a species difference in the degree of sensitivity to ultrasound-induced lung damage. This study was undertaken because it was hypothesized that the mouse may not be an acceptable or suitable animal model for studies that examine the effects of ultrasound on lung tissue for purposes of extrapolating or estimating the degree of potential damage in other species. The rabbit was selected for comparison to the mouse because the rabbit exhibited sufficient physiological and morphological differences from those of the mouse to test this hypothesis. Using exactly the same exposure conditions and lung assessment criteria, it appeared that the mouse lung was more sensitive to ultrasound-induced damage than that of the rabbit by a factor of between 2.8 and 3.6. Lung lesions in mice and rabbits were similar in character, but were much more severe and extensive in mice. Lesions in both species consisted of intraalveolar hemorrhage that appeared as dark red to red-black areas that were visible on the pleural surfaces and that extend within the lung parenchyma.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 10 条
[1]   LUNG DAMAGE FROM EXPOSURE TO PULSED ULTRASOUND [J].
CHILD, SZ ;
HARTMAN, CL ;
SCHERY, LA ;
CARSTENSEN, EL .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (08) :817-825
[2]  
CROSFILL ML, 1961, J PHYSIOL-LONDON, V158, P1, DOI 10.1113/jphysiol.1961.sp006750
[3]   MOUSE LUNG DAMAGE FROM EXPOSURE TO 30 KHZ ULTRASOUND [J].
OBRIEN, WD ;
ZACHARY, JF .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1994, 20 (03) :287-297
[4]  
PINKERTON KE, 1992, COMP BIOL NORMAL LUN, P121
[5]   COMPARATIVE QUANTITATIVE MORPHOLOGY OF MAMMALIAN LUNG DIFFUSING AREA [J].
TENNEY, SM ;
REMMERS, JE .
NATURE, 1963, 197 (486) :54-&
[6]  
TYLER WS, 1992, COMP BIOL NORMAL LUN, P37
[7]  
WEIBEL ER, 1971, BIOL HDB RESP CIRCUL, pCH51
[8]  
ZACHARY JF, 1994, IN PRESS VET PATHOL
[9]  
1992, ACOUSTIC OUTPUT MEAS
[10]  
1992, STANDARD REAL TIME D