IMAGE-RECONSTRUCTION OF SEQUENTIALLY SAMPLED ECHO-PLANAR DATA

被引:28
作者
HYDER, F
ROTHMAN, DL
BLAMIRE, AM
机构
[1] Department of Chemistry, Yale University, New Haven
[2] Department of Internal Medicine, Yale University, New Haven
[3] Department of Surgery, Yale University, New Haven
基金
美国国家卫生研究院;
关键词
MAGNETIC RESONANCE IMAGING; ECHO-PLANAR IMAGING; IMAGE RECONSTRUCTION; SEQUENTIAL SAMPLING; SIMULTANEOUS SAMPLING; K-SPACE TRAJECTORY; TIME-REVERSAL; GRADIENT-ECHO;
D O I
10.1016/0730-725X(94)00068-E
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
For echo-planar imaging (EPI), failure to time-reverse alternate echoes results in aliasing in the image. We encountered image artifacts in EPI acquired on a system with sequential sampling. After examining the source of these image artifacts, we concluded that the artifacts were a result of the type of sampling method used in data acquisition and the way the time-reversal of alternate echoes was carried out prior to Fourier transformation. Two methods are demonstrated to obtain artifact-free EPI with sequential data sampling.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 17 条
[1]  
Mansfield, Multi-planar image formation using NMR spin echoes, J. Phys. C, 10, pp. L55-L58, (1977)
[2]  
Tropper, Image reconstruction for the NMR echoplanar technique, and for a proposed adaptation to allow continuous data acquisition, J. Magn. Reson., 42, pp. 193-202, (1981)
[3]  
Johnson, Hutchison, The limitations of NMR recalled-echo planar imaging technique, J. Magn. Reson., 63, pp. 14-30, (1985)
[4]  
Twieg, Acquisition and accuracy in rapid NMR imaging methods, Magn. Reson. Med., 2, pp. 14-30, (1985)
[5]  
Ljunggren, A simple graphical representation of Fourier-based imaging methods, J. Magn. Reson., 54, pp. 338-343, (1983)
[6]  
Redfield, Kunz, Quadrature Fourier NMR detection: Simple multiplex for dual detection and discussion, J. Magn. Reson., 19, pp. 250-254, (1975)
[7]  
Sekihara, Kohno, New construction technique for echo-planar imaging to allow combined use of odd and even numbered echoes, Magn. Reson. Med., 5, pp. 485-491, (1987)
[8]  
Harris, Nuclear Magnetic Resonance Spectroscopy, pp. 79-93, (1986)
[9]  
Brigham, The Fast Fourier Transform and Its Applications, pp. 35-37, (1988)
[10]  
Bendel, Snapshot MRI with T<sub>2</sub><sup>∗</sup>-weighted magnetization preparation, Magn. Reson. Med., 30, pp. 399-402, (1993)