MEASUREMENT OF BLOOD-FLOW AND PERFUSION IN THE CARDIOVASCULAR-SYSTEM

被引:12
作者
HIGGINS, CB
CAPUTO, G
WENDLAND, MF
SAEED, M
机构
关键词
BLOOD FLOW; MAGNETIC RESONANCE IMAGING; PERFUSION;
D O I
10.1097/00004424-199212002-00012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Complete evaluation of cardiovascular disease by a single imaging technique requires measurement of bulk flow in blood vessels and estimation of relative or ideally absolute perfusion at the tissue level. Magnetic resonance (MR) measurement of blood flow in arteries and veins has been done using the velocity-encoded phase cine gradient echo technique. This technique has been applied with cine MR to measure normal and pathologically high velocities. Measurement of relative perfusion in the myocardium has used the intravenous injection of T1 relaxation enhancing and magnetic susceptibility MR contrast media with rapid image acquisition using echoplanar imaging. MR images (MRIs) acquired during steady-state distribution or during the first passage of these contrast media have depicted ischemic myocardial regions.
引用
收藏
页码:S66 / S71
页数:6
相关论文
共 20 条
[1]   BLOOD FLOWMETER UTILIZING NUCLEAR MAGNETIC RESONANCE [J].
BOWMAN, RL ;
KUDRAVCEV, V .
IRE TRANSACTIONS ON MEDICAL ELECTRONICS, 1959, 6 (04) :267-269
[2]  
BRENNER LD, 1991, IN PRESS J AM COLL C
[3]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[4]  
DULCE MC, 1992, IN PRESS RADIOLOGY
[5]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[6]   NUCLEAR MAGNETIC-RESONANCE IMAGING OF THE CARDIOVASCULAR-SYSTEM - NORMAL AND PATHOLOGIC FINDINGS [J].
HERFKENS, RJ ;
HIGGINS, CB ;
HRICAK, H ;
LIPTON, MJ ;
CROOKS, LE ;
LANZER, P ;
BOTVINICK, E ;
BRUNDAGE, B ;
SHELDON, PE ;
KAUFMAN, L .
RADIOLOGY, 1983, 147 (03) :749-759
[7]   THE POTENTIAL IMPACT OF NUCLEAR MAGNETIC-RESONANCE IMAGING ON CARDIOVASCULAR DIAGNOSIS [J].
KAUFMAN, L ;
CROOKS, L ;
SHELDON, P ;
HRICAK, H ;
HERFKENS, R ;
BANK, W .
CIRCULATION, 1983, 67 (02) :251-257
[8]   VALVE AND GREAT VESSEL STENOSIS - ASSESSMENT WITH MR JET VELOCITY MAPPING [J].
KILNER, PJ ;
FIRMIN, DN ;
REES, RSO ;
MARTINEZ, J ;
PENNELL, DJ ;
MOHIADDIN, RH ;
UNDERWOOD, SR ;
LONGMORE, DB .
RADIOLOGY, 1991, 178 (01) :229-235
[9]   RIGHT AND LEFT-VENTRICULAR STROKE VOLUME MEASUREMENTS WITH VELOCITY-ENCODED CINE MR IMAGING - INVITRO AND INVIVO VALIDATION [J].
KONDO, C ;
CAPUTO, GR ;
SEMELKA, R ;
FOSTER, E ;
SHIMAKAWA, A ;
HIGGINS, CB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (01) :9-16
[10]  
MORAN PR, 1982, MAGN RESON IMAGING, V1, P1976