CT ARTERIAL PORTOGRAPHY - CAUSES OF TECHNICAL FAILURE AND VARIABLE LIVER ENHANCEMENT

被引:62
作者
PAULSON, EK [1 ]
BAKER, ME [1 ]
HILLEREN, DJ [1 ]
JONES, WP [1 ]
KNELSON, MH [1 ]
NADEL, SN [1 ]
LEDER, RA [1 ]
MEYERS, WC [1 ]
机构
[1] DUKE UNIV,MED CTR,DEPT SURG,DURHAM,NC 27710
关键词
D O I
10.2214/ajr.159.4.1326885
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. We studied the causes of technical failure and enhancement variability encountered during CT arterial portography. MATERIALS AND METHODS. CT arterial portograms and digital arteriograms were obtained via the superior mesenteric artery before partial liver resection in 43 patients with malignant tumors. These studies were reviewed for causes of technical failure and variable enhancement. RESULTS. Eleven (26%) of 43 procedures were technical failures. Causes of failure included aortic injection after catheter dislodgement (four), dense hyperenhancement associated with laminar flow in the portal vein produced by rapid venous return from a selective injection into a proximal branch vessel of the superior mesenteric artery (two), premature scanning beginning at the iliac crest (two), reflux into a replaced right hepatic artery (one), hepatic arterial enhancement via the pancreaticoduodenal arcade (one), and portal hypertension (one). Of the 32 remaining studies, 28 showed areas of parenchymal hypoenhancement or hyperenhancement. Causes of variable enhancement included impaired portal vein perfusion from mass effect of the tumor, laminar flow in the portal vein, and focal fatty infiltration. CONCLUSION. Technical failures and enhancement variability are common in CT arterial portography. Factors leading to technical failure include catheter choice and position, portal hypertension, and operator error.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 21 条
[1]  
BRON KM, 1983, ABRAMS ANGIOGRAPHY V, P1609
[2]   Stream line phenomena in the portal vein and the selective distribution of portal blood in the liver [J].
Copher, GH ;
Dick, BM .
ARCHIVES OF SURGERY, 1928, 17 (03) :408-419
[3]   DYNAMIC CT OF HEPATIC MASSES USING INTRAARTERIAL ENHANCEMENT - ADVANTAGES AND PITFALLS [J].
DOLENZ, KB ;
LI, KCP ;
HAWKINS, IF ;
MILES, SG ;
ROS, PR ;
BLAND, KI .
GASTROINTESTINAL RADIOLOGY, 1990, 15 (03) :241-244
[4]   HEPATIC PSEUDOLESION - APPEARANCE OF FOCAL LOW ATTENUATION IN THE MEDIAL SEGMENT OF THE LEFT LOBE AT CT ARTERIAL PORTOGRAPHY [J].
FERNANDEZ, MD ;
BERNARDINO, ME .
RADIOLOGY, 1991, 181 (03) :809-812
[5]   HEPATIC PERFUSION ABNORMALITIES DURING CT ANGIOGRAPHY - DETECTION AND INTERPRETATION [J].
FREENY, PC ;
MARKS, WM .
RADIOLOGY, 1986, 159 (03) :685-691
[6]   COMPUTED TOMOGRAPHIC ARTERIOGRAPHY OF THE LIVER [J].
FREENY, PC ;
MARKS, WM .
RADIOLOGY, 1983, 148 (01) :193-197
[7]   DETECTION OF FOCAL HEPATIC MASSES - PROSPECTIVE EVALUATION WITH CT, DELAYED CT, CT DURING ARTERIAL PORTOGRAPHY, AND MR IMAGING [J].
HEIKEN, JP ;
WEYMAN, PJ ;
LEE, JKT ;
BALFE, DM ;
PICUS, D ;
BRUNT, EM ;
FLYE, MW .
RADIOLOGY, 1989, 171 (01) :47-51
[8]  
HUGHES KS, 1988, SURGERY, V103, P278
[9]   SKIP AREAS IN HEPATIC STEATOSIS - A SONOGRAPHIC-ANGIOGRAPHIC STUDY [J].
MARCHAL, G ;
TSHIBWABWATUMBA, E ;
VERBEKEN, E ;
VANROOST, W ;
VANSTEENBERGEN, W ;
BAERT, A ;
LAUWERIJNS, J .
GASTROINTESTINAL RADIOLOGY, 1986, 11 (02) :151-157
[10]   DYNAMIC COMPUTED-TOMOGRAPHY DURING ARTERIAL PORTOGRAPHY - THE MOST SENSITIVE EXAMINATION FOR SMALL HEPATOCELLULAR CARCINOMAS [J].
MATSUI, O ;
TAKASHIMA, T ;
KADOYA, M ;
IDA, M ;
SUZUKI, M ;
KITAGAWA, K ;
KAMIMURA, R ;
INOUE, K ;
KONISHI, H ;
ITOH, H .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (01) :19-24