CORROSION OF MODULAR HIP PROSTHESES

被引:127
作者
MATHIESEN, EB [1 ]
LINDGREN, JU [1 ]
BLOMGREN, GGA [1 ]
REINHOLT, FP [1 ]
机构
[1] KAROLINSKA INST,HUDDINGE UNIV HOSP,DEPT PATHOL,S-14186 HUDDINGE,SWEDEN
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 1991年 / 73卷 / 04期
关键词
D O I
10.1302/0301-620X.73B4.2071637
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Nine uncemented hip prostheses of modular design were revised because of late infection (2 cases), femoral stem loosening or fracture (2), loosening of threaded cups (3) and protrusion of bipolar cups (2). At surgery we found tissue discoloration and macroscopic corrosion in four of the nine prostheses, located at the head-neck junction. Histological examination in most cases showed extensive necrosis associated with metal particles, indicating metal toxicity. Metallographic examination of the prosthetic heads revealed structural imperfections and inhomogeneity of the metal. We suggest that the crevice between the head and neck is a potential site of corrosion in modular designs.
引用
收藏
页码:569 / 575
页数:7
相关论文
共 39 条
[1]  
APLEY AG, 1989, J BONE JOINT SURG BR, V71, P1
[2]   CHROMIUM CONCENTRATIONS IN SERUM, BLOOD CLOT AND URINE FROM PATIENTS FOLLOWING TOTAL HIP-ARTHROPLASTY [J].
BARTOLOZZI, A ;
BLACK, J .
BIOMATERIALS, 1985, 6 (01) :2-8
[3]   DOES CORROSION MATTER [J].
BLACK, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04) :517-520
[4]   EXCESSIVE METAL RELEASE DUE TO LOOSENING AND FRETTING OF SINTERED PARTICLES ON POROUS-COATED HIP PROSTHESES - REPORT OF 2 CASES [J].
BUCHERT, PK ;
VAUGHN, BK ;
MALLORY, TH ;
ENGH, CA ;
BOBYN, JD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (04) :606-609
[6]  
COLEMAN RF, 1973, BRIT MED J, P1527
[7]  
Cook S D, 1986, J Rehabil Res Dev, V23, P27
[8]   THE INVIVO PERFORMANCE OF 250 INTERNAL-FIXATION DEVICES - A FOLLOW-UP-STUDY [J].
COOK, SD ;
THOMAS, KA ;
HARDING, AF ;
COLLINS, CL ;
HADDAD, RJ ;
MILICIC, M ;
FISCHER, WL .
BIOMATERIALS, 1987, 8 (03) :177-184
[9]  
DOBBS HS, 1980, BIOMATERIALS, V1, P1933
[10]   THE INVITRO TOXICITY OF COBALT-CHROME-MOLYBDENUM ALLOY AND ITS CONSTITUENT METALS [J].
EVANS, EJ ;
THOMAS, IT .
BIOMATERIALS, 1986, 7 (01) :25-29