INVITRO VELOCITY-MEASUREMENTS IN THE NEAR VICINITY OF THE BJORK-SHILEY AORTIC PROSTHESIS USING A LASER-DOPPLER ANEMOMETER

被引:8
作者
YOGANATHAN, AP [1 ]
CORCORAN, WH [1 ]
HARRISON, EC [1 ]
CARL, JR [1 ]
机构
[1] UNIV SO CALIF,LOS ANGELES CTY MED CTR,DIV MED,CARDIOL SECT,LOS ANGELES,CA 90033
关键词
Björk-Shiley aortic valve; in vitro velocity measurements; Laser-Doppler anemometer Shear stress measurements; Thrombus formation; Tissue overgrowth;
D O I
10.1007/BF02447057
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In this study, in vitro velocity measurements in the near vicinity of a Björk-Shiley aortic valve, one of the more commonly used aortic valve prostheses, were made using a laser-Doppler anemometer. The velocity measurements identified a zone of stagnation, about 20 mm wide, immediately downstream from the fully open disc. The measurements also showed that the flow through the valve was divided into two unequal regions, namely, the major and minor outflow regions. Because of the low flow in the minor outflow region, the shear stresses along the perimeter of the valve in that region were considerably lower than the shear stresses along the sewing ring of the major outflow region. Pathologic studies of nine recovered Björk-Shiley aortic valves indicated varying amounts of thrombus formation on the outflow face of the disc and excess growth of endothelial tissue along the perimeter of the minor outflow region. If the large stagnation zone and the relatively low shear in the minor outflow region which were observed in the in vitro measurements also exist in vivo, they could lead to the clinically observed thrombus formation and tissue overgrowth, respectively. © 1979 IFMBE.
引用
收藏
页码:453 / 459
页数:7
相关论文
共 19 条
[1]   THROMBOSIS ON BJORK-SHILEY AORTIC-VALVE PROSTHESIS - CLINICAL, ARTERIOGRAPHIC, ECHOCARDIOGRAPHIC AND THERAPEUTIC OBSERVATIONS IN 7 CASES [J].
BENZVI, J ;
HILDNER, FJ ;
CHANDRARATNA, PAN ;
SAMET, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (05) :538-544
[2]  
BOZER AY, 1972, J CARDIOVASC SURG, V13, P141
[3]   DIAGNOSIS OF BJORK-SHILEY AORTIC-VALVE DYSFUNCTION BY ECHOCARDIOGRAPHY [J].
CHANDRARATNA, PAN ;
LOPEZ, JM ;
HILDNER, FJ ;
SAMET, P ;
BENZVI, J ;
GINDLESPERGER, D .
AMERICAN HEART JOURNAL, 1976, 91 (03) :318-324
[4]   THROMBOSIS OF 2 HIGH-FLOW PROSTHETIC VALVES [J].
COKKINOS, DV ;
VORIDIS, E ;
BAKOULAS, G ;
THEODOSSIOU, A ;
SKALKEAS, GD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1971, 62 (06) :947-+
[5]  
DAVILA JC, 1966, HEART SUBSTITUTES ME, P25
[6]   LATE THROMBOSIS OF AORTIC BJORK-SHILEY PROSTHESIS - ITS CLINICAL RECOGNITION AND MANAGEMENT [J].
FERNANDEZ, J ;
SAMUEL, A ;
YANG, SS ;
SUMATHISENA ;
GOOCH, A ;
MARANHAO, V ;
LEMOLE, GM ;
GOLDBERG, H .
CHEST, 1976, 70 (01) :12-16
[7]  
FIGLIOLA RS, 1976, THESIS U NOTRE DAME
[8]  
KINGSLEY B, 1967, ENGINEERING PRACTICE
[9]   FACTORS INFLUENCING THROMBUS FORMATION - IN VIVO [J].
MUSTARD, JF ;
DOWNIE, HG ;
MURPHY, EA ;
ROWSELL, HC .
AMERICAN JOURNAL OF MEDICINE, 1962, 33 (05) :621-+
[10]  
MUSTARD JF, 1963, CIRC RES, V12, P441