THE EFFECT OF AIR HUMIDIFICATION ON SYMPTOMS AND PERCEPTION OF INDOOR AIR-QUALITY IN OFFICE WORKERS - A 6-PERIOD CROSS-OVER TRIAL

被引:91
作者
REINIKAINEN, LM
JAAKKOLA, JJK
SEPPANEN, O
机构
[1] HELSINKI UNIV TECHNOL, HEATING VENTILATING & AIR CONDITIONING LAB, OTAKAARI 4A, SF-02150 ESPOO, FINLAND
[2] UNIV HELSINKI, DEPT PUBL HLTH, SF-00100 HELSINKI 10, FINLAND
来源
ARCHIVES OF ENVIRONMENTAL HEALTH | 1992年 / 47卷 / 01期
关键词
D O I
10.1080/00039896.1992.9935938
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The objective of this study was to evaluate the effect of air humidification on (a) the dryness of the skin and mucosa, (b) allergic and asthmatic reactions, and (c) the perception of indoor air quality. A total of 290 office workers at the Pasila Office Center were included in a six-period cross-over trial. One wing of the building was operated with 30-40% humidification, and the other wing operated under conditions of no air humidification (relative humidity from natural conditions was 20-30%). The length of each study period was 1 work wk. The workers were instructed to keep a structured daily diary of their symptoms, their perception of the indoor air, and potential determinants of the symptoms. A total of 211 (72.6%) workers who returned at least two weekly diaries, and who had experienced both humidified and nonhumidified conditions, were included in the analyses. The primary outcome-dryness symptom score-was characterized by dryness, irritation or itching of the skin and eyes, dryness or irritation of the throat, and nasal dryness. Means of the daily symptom scores and perception ratings during the humidified and nonhumidified periods were calculated for each participant, and intraindividual differences in the means were used to assess the effect of air humidification. The dryness symptom score was significantly smaller during the humidified phase than during the reference phase (paired t test; p < .05). Allergic symptoms that were considered as a separate outcome, a sensation of dryness, and draft were also significantly less frequent during the humidification phase (p < .05). The perception of stuffy air increased during the humidification phase (p < .01). These results suggest that dryness of the skin and mucosa, allergic reactions, and the sensation of dryness can be alleviated by proper air humidification.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 9 条
[1]  
Akimenko V.V., 1986, INDOOR AIR, V6, P87
[2]   SICK BUILDING SYNDROME - A STUDY OF 4373 OFFICE WORKERS [J].
BURGE, S ;
HEDGE, A ;
WILSON, S ;
BASS, JH ;
ROBERTSON, A .
ANNALS OF OCCUPATIONAL HYGIENE, 1987, 31 (04) :493-504
[3]   THE SICK BUILDING SYNDROME - PREVALENCE STUDIES [J].
FINNEGAN, MJ ;
PICKERING, CAC ;
BURGE, PS .
BRITISH MEDICAL JOURNAL, 1984, 289 (6458) :1573-1575
[4]  
Harrison J., 1987, INDOOR AIR 87, V2, P487
[5]   SICK BUILDING SYNDROME, SENSATION OF DRYNESS AND THERMAL COMFORT IN RELATION TO ROOM-TEMPERATURE IN AN OFFICE BUILDING - NEED FOR INDIVIDUAL CONTROL OF TEMPERATURE [J].
JAAKKOLA, JJK ;
HEINONEN, OP ;
SEPPANEN, O .
ENVIRONMENT INTERNATIONAL, 1989, 15 (1-6) :163-168
[6]  
JAAKKOLA JK, 1986, THESIS U HELSINKI HE
[7]   NOTE ON THE SAMPLING ERROR OF THE DIFFERENCE BETWEEN CORRELATED PROPORTIONS OR PERCENTAGES [J].
McNemar, Quinn .
PSYCHOMETRIKA, 1947, 12 (02) :153-157
[8]  
MIETTINEN OS, 1985, PRINCIPLES OCCURRENC
[9]   THE EFFECT OF AIR HUMIDIFICATION ON DIFFERENT SYMPTOMS IN OFFICE WORKERS - AN EPIDEMIOLOGIC-STUDY [J].
REINIKAINEN, LM ;
JAAKKOLA, JJK ;
HEINONEN, OP .
ENVIRONMENT INTERNATIONAL, 1991, 17 (04) :243-250