With the development of models to predict fire growth and spread in buildings, there has been a concomitant evolution in the measurement and analysis of experimental data in real-scale fires. This report presents the types of analyses that can be used to examine large-scale room fire test data to prepare the data for comparison with zone-based fire models. Five sets of experimental data which can be used to test the limits of a typical two-zone fire model are detailed. A standard set of nomenclature describing the geometry of the building and the quantities measured in each experiment is presented. Availability of ancillary data (such as smaller-scale test results) is included. These descriptions, along with the data (available in computer-readable form) should allow comparisons between the experiment and model predictions. The base of experimental data ranges in complexity from one room tests with individual furniture items to a series of tests conducted in a multiple story hotel equipped with a zoned smoke control system.
引用
收藏
页码:411 / 462
页数:52
相关论文
共 93 条
[1]  
AHONEN A, 1986, VTT383 VALT TEKN TUT
[2]  
ALPERT RL, 1977, FMRC OAOR2BU1 FACT M
[3]  
ALPERT RL, 1977, FMRC OAOR2BU7 FACT M
[4]  
ALPERT RL, 1977, FMRC OAOR2BU3 FACT M
[5]  
ALPERT RL, 1977, FMRC OAOR2BU2 FACT M
[6]  
ALPERT RL, 1977, FMRC OAOR2BU6 FACT M
[7]  
ALPERT RL, 1977, FMRC OAOR2BU4 FACT M
[8]  
ALPERT RL, 1975, FMRC210116 FACT MUT, V1
[9]  
ALPERT RL, 1977, FMRC OAOR2BU5 FACT M
[10]   A NOTE ON THE MEASUREMENT OF SMOKE YIELDS [J].
ATKINSON, G ;
DRYSDALE, DD .
FIRE SAFETY JOURNAL, 1989, 15 (04) :331-335