COMPARISON OF INTRAARTERIAL WITH CONTINUOUS NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN POSTOPERATIVE PEDIATRIC-PATIENTS

被引:24
作者
TRIEDMAN, JK
SAUL, JP
机构
[1] Department of Cardiology, Children's Hospital, Boston, 02115, MA
来源
JOURNAL OF CLINICAL MONITORING | 1994年 / 10卷 / 01期
关键词
BLOOD PRESSURE; PEDIATRIC INTENSIVE CARE;
D O I
10.1007/BF01651461
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective. The purpose of this study was to estimate the accuracy, bias, and frequency response of continuous blood pressure monitoring using finger photoplethysmography in children. Methods. To compare arterial blood pressure measured using the Finapres device with simultaneously measured intraarterial blood pressure we studied 27 randomly selected postoperative pediatric patients who were receiving a variety of inotropic and vasoactive agents at a cardiac intensive care unit in university-affiliated pediatric hospital. Results. Sixty-two of 66 attempts (94%) to obtain a noninvasive blood pressure measurement were successful. A total of 37,351 paired blood pressure measurements from 53 records were compared, revealing a measurement bias of -18.6 mm Hg for systolic blood pressure and -13.4 mm Hg for diastolic blood pressure. The measurement bias increased proportionately to blood pressure, with systolic and diastolic gains between the noninvasive and intraarterial techniques of 0.86 and 0.75 mm Hg/mm Hg, respectively. The variation bias during each recording epoch, as measured by standard deviation of bias, was low (mean sigma(systolic) = 2.9 mm Hg; mean sigma(diastolic) = 2.0 mm Hg). The frequency response between the intraarterial and noninvasive pressure waveforms was flat to 10 Hz and approximately equal to 1. Conclusions. Substantial measurement bias exists between this noninvasive blood pressure measurement technique and intraarterial blood pressure. Measurements of the intrapatient variability and frequency response analysis suggest that the noninvasive technique accurately tracks intraarterial blood pressure over the short term. This technique may have useful applications in settings where intraarterial monitoring is undesirable or unobtainable.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 32 条
[1]  
[Anonymous], 1989, HEMODYNAMICS
[2]  
Blackman RB, 1959, MEASUREMENT POWER SP
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]  
BOEHMER RD, 1987, J CLIN MONITOR, V3, P282
[5]  
BRIGHAM EO, 1991, FAST FOURIER TRANSFO
[6]   AUSCULTATORY MEAN BLOOD-PRESSURE [J].
DAVIS, GJ ;
GEDDES, LA .
JOURNAL OF CLINICAL MONITORING, 1990, 6 (04) :261-265
[7]  
Davis R F, 1985, J Clin Monit, V1, P114, DOI 10.1007/BF02832198
[8]   EFFECTS OF PERIPHERAL VASOCONSTRICTION ON THE BLOOD-PRESSURE IN THE FINGER, MEASURED CONTINUOUSLY BY A NEW NONINVASIVE METHOD (THE FINAPRES) [J].
DORLAS, JC ;
NIJBOER, JA ;
BUTIJN, WT ;
VANDERHOEVEN, GMA ;
SETTELS, JJ ;
WESSELING, KH .
ANESTHESIOLOGY, 1985, 62 (03) :342-345
[9]  
EAST T D, 1987, Anesthesiology (Hagerstown), V67, pA186, DOI 10.1097/00000542-198709001-00186
[10]   COMPARATIVE ACCURACIES OF A FINGER BLOOD-PRESSURE MONITOR AND AN OSCILLOMETRIC BLOOD-PRESSURE MONITOR [J].
EPSTEIN, RH ;
HUFFNAGLE, S ;
BARTKOWSKI, RR .
JOURNAL OF CLINICAL MONITORING, 1991, 7 (02) :161-167