COAMPLIFICATION OF HIV TYPE-1 AND BETA-GLOBIN GENE DNA-SEQUENCES IN A NONISOTOPIC POLYMERASE CHAIN-REACTION ASSAY TO CONTROL FOR AMPLIFICATION EFFICIENCY

被引:15
作者
COUTLEE, F
HE, YL
SAINTANTOINE, P
OLIVIER, C
KESSOUS, A
机构
[1] UNIV MONTREAL, DEPT PATHOL, MONTREAL, PQ H3C 3J7, CANADA
[2] UNIV MONTREAL, DEPT MICROBIOL, MONTREAL, PQ H3C 3J7, CANADA
[3] UNIV MONTREAL, NOTRE DAME HOSP, LOUIS CHARLES SIMARD RES CTR, MONTREAL, PQ H2L 4M1, CANADA
[4] CLIN MED ACTUEL, MONTREAL, PQ, CANADA
关键词
D O I
10.1089/aid.1995.11.363
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
The polymerase chain reaction (PCR) fails to detect HIV-1 sequences in 5% of infected individuals.(1-3) To screen for false-negative PCR tests, we developed a nonisotopic PCR assay in which sequences from the beta-globin gene and from the HIV-1 vpu-env region were coamplified with biotinylated and fluorescein-labeled primers, respectively, Coamplified products were reacted with specific internal digoxigenin-labeled RNA probes, Hybrids were detected in a microtiter plate coated with streptavidin or anti-fluorescein antibody, with enzyme-labeled anti-digoxigenin antibody, After the optimization of the coamplification conditions, the assay could detect 5 proviral DNA copies in a lysate from 100,000 peripheral blood mononuclear cells, Fifty-seven samples from 55 HIV-1-seropositive patients and 25 samples from 25 seronegative individuals were evaluated. Fifty-two samples from HIV-infected individuals were positive for HIV-1 vpu-env sequences, Three of the 5 PBMC lysates falsely negative for HIV-1 sequences had reactivities for beta-globin (3-23 fu) below that of 100,000 cells (304 fu). Nonisotopic coamplification allowed for the evaluation of the quality of specimens for PCR concurrently with the detection of the presence of viral template sequences.
引用
收藏
页码:363 / 371
页数:9
相关论文
共 46 条
  • [2] GENITAL HUMAN PAPILLOMAVIRUS INFECTION IN FEMALE UNIVERSITY-STUDENTS AS DETERMINED BY A PCR-BASED METHOD
    BAUER, HM
    TING, Y
    GREER, CE
    CHAMBERS, JC
    TASHIRO, CJ
    CHIMERA, J
    REINGOLD, A
    MANOS, MM
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (04): : 472 - 477
  • [3] BUSCH MP, 1992, NEW ENGL J MED, V326, P64, DOI 10.1056/NEJM199201023260114
  • [5] COMPARISON OF SPOT-BLOT AND MICROTITRE PLATE METHODS FOR THE DETECTION OF HIV-1 PCR PRODUCTS
    CONWAY, B
    BECHTEL, LJ
    ADLER, KA
    DAQUILA, RT
    KAPLAN, JC
    HIRSCH, MS
    [J]. MOLECULAR AND CELLULAR PROBES, 1992, 6 (03) : 245 - 249
  • [6] THE POLYMERASE CHAIN-REACTION - A NEW TOOL FOR THE UNDERSTANDING AND DIAGNOSIS OF HIV-1 INFECTION AT THE MOLECULAR-LEVEL
    COUTLEE, F
    VISCIDI, RP
    SAINTANTOINE, P
    KESSOUS, A
    YOLKEN, RH
    [J]. MOLECULAR AND CELLULAR PROBES, 1991, 5 (04) : 241 - 259
  • [7] ENZYME-IMMUNOASSAY FOR DETECTION OF HYBRIDS BETWEEN PCR-AMPLIFIED HIV-1 DNA AND A RNA PROBE - PCR-EIA
    COUTLEE, F
    YANG, BZ
    BOBO, L
    MAYUR, K
    YOLKEN, R
    VISCIDI, R
    [J]. AIDS RESEARCH AND HUMAN RETROVIRUSES, 1990, 6 (06) : 775 - 784
  • [8] DISCORDANCE BETWEEN PRIMER PAIRS IN THE POLYMERASE CHAIN-REACTION FOR DETECTION OF HUMAN-IMMUNODEFICIENCY-VIRUS TYPE-1 - A ROLE FOR TAQ POLYMERASE INHIBITORS
    COUTLEE, F
    SAINTANTOINE, P
    OLIVIER, C
    KESSOUSELBAZ, A
    VOYER, H
    BERRADA, F
    BEGIN, P
    GIROUX, L
    VISCIDI, R
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1991, 164 (04) : 817 - 818
  • [9] IMMUNODETECTION OF DNA WITH BIOTINYLATED RNA PROBES - A STUDY OF REACTIVITY OF A MONOCLONAL-ANTIBODY TO DNA RNA HYBRIDS
    COUTLEE, F
    BOBO, L
    MAYUR, K
    YOLKEN, RH
    VISCIDI, RP
    [J]. ANALYTICAL BIOCHEMISTRY, 1989, 181 (01) : 96 - 105
  • [10] ABSENCE OF PROLONGED IMMUNOSILENT INFECTION WITH HUMAN-IMMUNODEFICIENCY-VIRUS IN INDIVIDUALS WITH HIGH-RISK BEHAVIORS
    COUTLEE, F
    OLIVIER, C
    CASSOL, S
    VOYER, H
    KESSOUSELBAZ, A
    SAINTANTOINE, P
    HE, YL
    FAUVEL, M
    [J]. AMERICAN JOURNAL OF MEDICINE, 1994, 96 (01) : 42 - 48