VALIDATION OF FLUORESCENT-LABELED MICROSPHERES FOR MEASUREMENT OF REGIONAL ORGAN PERFUSION

被引:315
作者
GLENNY, RW [1 ]
BERNARD, S [1 ]
BRINKLEY, M [1 ]
机构
[1] MOLEC PROBES INC,EUGENE,OR 97402
关键词
BLOOD FLOW; PULMONARY; HEART; KIDNEY;
D O I
10.1152/jappl.1993.74.5.2585
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 mum diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs while reference blood samples were simultaneously withdrawn from a femoral artery in the pigs. The lungs were cubed into approximately 2 cm3 pieces (n = 1,510). Each pig heart and kidney was cubed into approximately 1-g pieces (total n = 192 and 120, respectively). The radioactivity of each organ piece and reference blood sample was determined using a scintillation counter with count rates corrected for decay, background, and spillover. Tissue samples and reference blood samples were digested with KOH and filtered and the fluorescent dye was extracted with a solvent, or the dye was extracted from lung tissue without filtering. The fluorescence of each sample was determined for each color by use of an automated spectrophotometer. Perfusion was calculated for each organ piece from both the radioactivity and fluorescence. Correlation between flow determined by radio- and fluorescent-labeled microspheres was as follows: r = 0.98 +/- 0.01 (SD) (lung, filtered, n = 588), r = 0.99 +/- 0.00 (lung, nonfiltered, n = 710), r = 0.95 +/- 0.02 (heart, filtered), and r = 0.96 +/- 0.02 (kidney, filtered). Compared with colored microspheres, methods for quantitating fluorescent-labeled microspheres are more sensitive, less labor intensive, and less expensive. Fluorescent-labeled microspheres provide a new nonradioactive method for single and repeated measurement of regional organ perfusion.
引用
收藏
页码:2585 / 2597
页数:13
相关论文
共 19 条
[1]   QUANTITATING ERROR IN BLOOD-FLOW MEASUREMENTS WITH RADIOACTIVE MICROSPHERES [J].
AUSTIN, RE ;
HAUCK, WW ;
ALDEA, GS ;
FLYNN, AE ;
COGGINS, DL ;
HOFFMAN, JIE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (01) :H280-H288
[2]  
BAER RW, 1984, AM J PHYSIOL, V246, pH1418
[3]   VALIDITY OF MICROSPHERE DEPOSITIONS FOR REGIONAL MYOCARDIAL FLOWS [J].
BASSINGTHWAIGHTE, JB ;
MALONE, MA ;
MOFFETT, TC ;
KING, RB ;
LITTLE, SE ;
LINK, JM ;
KROHN, KA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1987, 253 (01) :H184-H193
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[6]  
GOTTLIEB GJ, 1981, AM J PATHOL, V103, P292
[7]  
GUILBAULT GG, 1990, MODERN MONOGRAPHS AN, V3
[8]   EVALUATION OF NONRADIOACTIVE, COLORED MICROSPHERES FOR MEASUREMENT OF REGIONAL MYOCARDIAL BLOOD-FLOW IN DOGS [J].
HALE, SL ;
ALKER, KJ ;
KLONER, RA .
CIRCULATION, 1988, 78 (02) :428-434
[9]   FLUORESCENT MICROSPHERES - A NEW TOOL FOR VISUALIZATION OF ISCHEMIC MYOCARDIUM IN RATS [J].
HALE, SL ;
VIVALDI, MT ;
KLONER, RA .
AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 251 (04) :H863-H868
[10]   BLOOD-FLOW MEASUREMENTS WITH RADIONUCLIDE-LABELED PARTICLES [J].
HEYMANN, MA ;
PAYNE, BD ;
HOFFMAN, JIE ;
RUDOLPH, AM .
PROGRESS IN CARDIOVASCULAR DISEASES, 1977, 20 (01) :55-79