APPLICATIONS OF WIRED PEROXIDASE ELECTRODES FOR PEROXIDE DETERMINATION IN LIQUID-CHROMATOGRAPHY COUPLED TO OXIDASE IMMOBILIZED ENZYME REACTORS

被引:94
作者
YANG, L
JANLE, E
HUANG, TH
GITZEN, J
KISSINGER, PT
VREEKE, M
HELLER, A
机构
[1] BIOANALYT SYST INC,W LAFAYETTE,IN 47906
[2] UNIV TEXAS,DEPT CHEM ENGN,AUSTIN,TX 78712
关键词
D O I
10.1021/ac00104a005
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An osmium poly(vinylpyridine) redox polymer ''wired'' horseradish peroxidase electrode has been used to detect H2O2 for the determination of glucose, lactate, and acetylcholine/choline with liquid chromatography (LC) and postcolumn immobilized enzyme reactors (IMERs). The redox polymer film containing peroxidase is coated on the surface of a glassy carbon electrode and operated at +100 mV vs Ag/AgCl for the reduction of H2O2. Compared with a conventional platinum electrode oxidizing H2O2 at +500 mV vs Ag/AgCl, the peroxidase cathode exhibits a 2-10-fold improvement in sensitivity and detection limit. The enzyme electrode also shows better operational stability than the Pt electrode. When the enzyme electrode is coupled to LC oxidase IMER systems, the initial stabilization of the background current is significantly faster than that for the conventional Pt electrode. The enzyme electrode has been used to determine glucose and lactate concentrations in rat subcutaneous microdialysates. After 8 days of continuous injection of the dialysate samples, the enzyme electrode sensitivity dropped by only 5%.
引用
收藏
页码:1326 / 1331
页数:6
相关论文
共 24 条
[1]  
BACK HK, 1992, J AM CHEM SOC, V114, P718
[2]   PEROXIDASE-MODIFIED CARBON-FIBER MICROELECTRODES IN FLOW-THROUGH DETECTION OF HYDROGEN-PEROXIDE AND ORGANIC PEROXIDES [J].
CSOREGI, E ;
GORTON, L ;
MARKOVARGA, G ;
TUDOS, AJ ;
KOK, WT .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3604-3610
[3]  
Damsma G, 1991, MICRODIALYSIS NEUROS, P237
[4]   DETERMINATION OF PLASMA CHOLINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A POSTCOLUMN ENZYME REACTOR AND ELECTROCHEMICAL DETECTION [J].
FOSSATI, T ;
COLOMBO, M ;
CASTIGLIONI, C ;
ABBIATI, G .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 656 (01) :59-64
[5]   QUANTITATION OF CHOLINE IN THE EXTRACELLULAR FLUID OF BRAIN-TISSUE WITH AMPEROMETRIC MICROSENSORS [J].
GARGUILO, MG ;
MICHAEL, AC .
ANALYTICAL CHEMISTRY, 1994, 66 (17) :2621-2629
[6]   REDOX POLYMER-FILMS CONTAINING ENZYMES .1. A REDOX-CONDUCTING EPOXY CEMENT - SYNTHESIS, CHARACTERIZATION, AND ELECTROCATALYTIC OXIDATION OF HYDROQUINONE [J].
GREGG, BA ;
HELLER, A .
JOURNAL OF PHYSICAL CHEMISTRY, 1991, 95 (15) :5970-5975
[7]  
HENDJI AN, 1993, SENSOR ACTUAT B-CHEM, V15, P127, DOI 10.1016/0925-4005(93)85038-C
[8]   A NEEDLE-TYPE ENZYME-BASED LACTATE SENSOR FOR IN-VIVO MONITORING [J].
HU, YB ;
ZHANG, YN ;
WILSON, GS .
ANALYTICA CHIMICA ACTA, 1993, 281 (03) :503-511
[9]  
HUANG T, 1989, CURR SEP, V9, P9
[10]  
JANLE EM, UNPUB