OXIMETRY IN CHILDREN RECOVERING FROM DEEP HYPOTHERMIA FOR CARDIAC-SURGERY

被引:13
作者
MACNAB, AJ
BAKERBROWN, G
ANDERSON, EE
机构
[1] Pediatric Intensive Care Unit, BC Children's Hospital, Vancouver, BC V6H 2N1
关键词
D O I
10.1097/00003246-199010000-00003
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Although pulse oximetry is a potentially useful diagnostic tool in the treatment of children after major open heart surgery, there are concerns regarding its reliability for measuring oxygen saturation (SaO2) in hypothermic or low perfusion states. To test pulse oximeter reliability in children under these conditions, our study compared 187 SaO2 pulse oximeter readings (Biox 3700) with simultaneous hemoximeter (OSM2, Radiometer) readings from 56 children rewarming after open heart surgery. Ages ranged from 4 months to 18 yr; temperatures ranged from 23.5° to 38°C (toe) and 31.3° to 40.8°C (core). The mean pulse oximeter SaO2 reading was 94.90% (SD 7.18, range 54% to 100%), mean hemoximeter reading was 96.07% (SD 7.06; minimum 54%; maximum 100%). The correlation between the readings was high (r = .88, p < .005), and was not affected by low core temperature. When oximeter and cardiac monitor pulse rates coincided, the oximeter SaO2 value was within ±5% (p < .05). We conclude that the Biox 3700 oximeter is reliable for noninvasive SaO2 monitoring in mild to moderately hypothermic children after open heart surgery, particularly when oximeter and cardiac heart rates coincide. Further studies are needed to confirm our findings in children with core temperatures <31.3°C, and when other oximeters are used.
引用
收藏
页码:1066 / 1069
页数:4
相关论文
共 19 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]  
CAMERON PD, 1985, ANAESTH INTENS CARE, V13, P202
[3]   WHAT DIFFERENCE DOES PULSE OXIMETRY MAKE [J].
COHEN, DE ;
DOWNES, JJ ;
RAPHAELY, RC .
ANESTHESIOLOGY, 1988, 68 (02) :181-183
[4]   FALSELY NORMAL SATURATION READING WITH THE PULSE OXIMETER [J].
COSTARINO, AT ;
DAVIS, DA ;
KEON, TP .
ANESTHESIOLOGY, 1987, 67 (05) :830-831
[5]   A SINGLE-BLIND STUDY OF PULSE OXIMETRY IN CHILDREN [J].
COTE, CJ ;
GOLDSTEIN, EA ;
COTE, MA ;
HOAGLIN, DC ;
RYAN, JF .
ANESTHESIOLOGY, 1988, 68 (02) :184-188
[6]   STATISTICAL TESTS FOR MODERATOR VARIABLES - FLAWS IN ANALYSES RECENTLY PROPOSED [J].
CRONBACH, LJ .
PSYCHOLOGICAL BULLETIN, 1987, 102 (03) :414-417
[7]   NONINVASIVE ARTERIAL HEMOGLOBIN OXYGEN-SATURATION VERSUS TRANS-CUTANEOUS OXYGEN-TENSION MONITORING IN THE PRETERM INFANT [J].
DECKARDT, R ;
STEWARD, DJ .
CRITICAL CARE MEDICINE, 1984, 12 (11) :935-939
[8]   PULSE OXIMETRY AND POSTOPERATIVE HYPOTHERMIA - AN EVALUATION OF THE NELLCOR N-100 IN A CARDIAC SURGICAL INTENSIVE-CARE UNIT [J].
GABRIELCZYK, MR ;
BUIST, RJ .
ANAESTHESIA, 1988, 43 (05) :402-404
[9]  
KESSLER MR, 1986, ANESTHESIOLOGY, V65, P437
[10]  
LAWSON D, 1987, ANESTHESIOLOGY, V67, P299