DONOR/RECIPIENT AORTA SIZE MISMATCH IN HEART-TRANSPLANTATION - A TECHNICAL ALTERNATIVE

被引:6
作者
DELEUZE, PH
MAZZUCOTELLI, JP
BENVENUTI, C
APTECAR, E
MOURTADA, A
BENHAIEMSIGAUX, N
HABACH, B
LOISANCE, DY
CACHERA, JP
机构
[1] Cardiothoracic Surgery Department, Pathology Laboratory, Henri Mondor Hospital, Creteil
关键词
D O I
10.1111/j.1540-8191.1994.tb00827.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A technical alternative is proposed to enable transplantation in cases of considerable size mismatch between donor and recipient aorta: interposition of a Dacron graft of intermediate diameter. This procedure was performed in a 56-year-old patient weighing 75 kg in whom a heart from a 40-kg donor was implanted.
引用
收藏
页码:70 / 73
页数:4
相关论文
共 5 条
[1]  
Lower RR, Shumway NE, Studies on the orthotopic homotransplantation of the canine heart, Surg Forum, 11, pp. 18-20, (1960)
[2]  
Costanzo-Nordin MR, Liao Y, Grusk BB, Et al., Oversizing of donor hearts: Beneficial or detrimental, J Heart Lung Transplant, 10, pp. 717-730, (1991)
[3]  
Chan BB, Fleischer KJ, Bergin JD, Et al., Weight is not an accurate criterion for adult cardiac transplant size matching, Ann Thorac Surg, 52, pp. 1230-1235, (1991)
[4]  
Sethi GK, Lanauze P, Rosado W, Et al., Clinical significance of weight difference between donor and recipient in heart transplantation, J Thorac Cardiovasc Surg, 106, pp. 444-448, (1993)
[5]  
Dreyfus G, Jebara V, Mihaileanu S, Et al., Total orthotopic heart transplantation: An alternative to the standard technique, Ann Thorac Surg, 52, pp. 1181-1184, (1991)