HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC EVALUATION OF PYRIDOXYL 5'-PHOSPHATE HEMOGLOBIN DERIVATIVES PRODUCED BY DIFFERENT REDUCTION PROCEDURES

被引:5
作者
FISHMAN, RM
MOORE, GL
ZEGNA, A
MARINI, MA
机构
[1] Letterman Army Institute of Research, Division of Blood Research, Presidio of San Francisco
来源
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS | 1990年 / 532卷 / 01期
关键词
D O I
10.1016/S0378-4347(00)83751-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pyridoxylated hemoglobin derivatives have been studied by many investigators. In this study hemoglobin A0 rather than stroma-free hemoglobin was used as a starting material in order to reduce the number of proteins to A0 and A1c. Derivatives were characterized using a Synchropak Q300 strong anion-exchange column, a POlyCAT A weak cation-exchange column and a VYDAC reversed-phase high-performance liquid chromatographic column. Resulting peak profiles of these two ion-exchange separations demonstrated enhanced resolution and showed the presence of pyridoxylated hemoglobin products not previously described. We compared products from the reduction of these Schiff base derivatives using either sodium borohydride or sodium cyanoborohydride reduction procedures. The sodium cyanoborohydride reduction method produced a lower percentage of products with multiple-site pyridoxylation modifications than the sodium borohydride reduction process. © 1990.
引用
收藏
页码:55 / 64
页数:10
相关论文
共 14 条
[1]  
BENESCH R, 1982, J BIOL CHEM, V257, P1320
[2]   AFFINITY LABELING OF POLYPHOSPHATE BINDING-SITE OF HEMOGLOBIN [J].
BENESCH, RE ;
BENESCH, R ;
RENTHAL, RD ;
MAEDA, N .
BIOCHEMISTRY, 1972, 11 (19) :3576-&
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF HUMAN HEMOGLOBINS - SIMULTANEOUS QUANTITATION OF FETAL AND GLYCATED HEMOGLOBINS [J].
BISSE, E ;
WIELAND, H .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 434 (01) :95-110
[4]  
BOLIN RB, 1983, ADV BLOOD SUBSTITUTE
[5]   PREPARATION OF HUMAN HEMOGLOBIN-AO FOR POSSIBLE USE AS A BLOOD SUBSTITUTE [J].
CHRISTENSEN, SM ;
MEDINA, F ;
WINSLOW, RW ;
SNELL, SM ;
ZEGNA, A ;
MARINI, MA .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1988, 17 (02) :143-154
[6]  
DEVENUTO F, 1979, SURG GYNECOL OBSTET, V149, P417
[7]   PREPARATION AND EVALUATION OF PYRIDOXALATED POLYMERIZED HUMAN-HEMOGLOBIN [J].
DEVENUTO, F ;
ZEGNA, A .
JOURNAL OF SURGICAL RESEARCH, 1983, 34 (03) :205-212
[8]   GLYCATED HEMOGLOBINS [J].
FLUCKIGER, R ;
MORTENSEN, HB .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 429 :279-292
[9]   A CRITICAL-EXAMINATION OF THE REACTION OF PYRIDOXAL 5-PHOSPHATE WITH HUMAN-HEMOGLOBIN AO [J].
MARINI, MA ;
MOORE, GL ;
FISHMAN, RM ;
JESSEE, R ;
MEDINA, F ;
SNELL, SM ;
ZEGNA, AI .
BIOPOLYMERS, 1989, 28 (12) :2071-2083
[10]   HEMOGLOBIN-BASED BLOOD SUBSTITUTES - CHARACTERIZATION OF 5 PYRIDOXAL 5'-PHOSPHATE DERIVATIVES OF HEMOGLOBIN [J].
MCGARRITY, MJ ;
ER, SS ;
HSIA, JC .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :37-50