The protection offered occupants of stationary automobiles against airborne gases and respirable particles such as might result from an accidental release, was measured and found to be substantial. For the four autos tested with the air conditioning (AC) system on and in recirculate position, the equilibrium ratios of inside/outside concentrations (I/O) for 2-mum diameter particles were less than 0.2 and some ratios were as small as 0.014. With both the AC compressor and the system fan off, the I/O for five autos ranged from 0.04 to 0.18. These low ratios are primarily a result of deposition within the autos. However, three of the five autos had substantially higher I/O ratios when the AC fan was on than when off, indicating that for some autos the AC caused significant added intake of outside air. Air exchange rates for the five stationary autos were on the order of 0.5 h-1 with AC off, and 2.5 h-1 with AC on.
引用
收藏
页码:3119 / 3125
页数:7
相关论文
共 10 条
[1]  
BIRENZVIGE A, 1983, ARCSLTR82093 CHEM SY
[2]  
CHESTER CV, 1988, ORNLTM10423
[3]  
CRISTY GA, 1981, ORNL5519
[4]   SHELTERING EFFECTIVENESS AGAINST PLUTONIUM PROVIDED BY BUILDINGS [J].
ENGELMANN, RJ .
ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (11) :2037-2044
[5]  
ENGELMANN RJ, 1991, ATDD91XX NAT OC ATM
[6]  
PETERSON FA, 1975, JAPCA-INT J AIR POLL, V25, P1029
[7]  
SEHMEL GA, 1984, DOETIC27601 US DEP E
[8]  
SHAIR FH, 1974, ENVIRON SCI TECHNOL, V18, P444
[9]   ESTIMATION OF INFILTRATION FROM LEAKAGE AND CLIMATE INDICATORS [J].
SHERMAN, MH .
ENERGY AND BUILDINGS, 1987, 10 (01) :81-86
[10]  
Wadden R. A., 1983, INDOOR AIR POLLUTION