BIOELECTRICAL IMPEDANCE ANALYSIS IN THE MEASUREMENT OF THE BODY-COMPOSITION OF SURGICAL PATIENTS

被引:23
作者
FEARON, KCH
RICHARDSON, RA
HANNAN, J
COWAN, S
WATSON, W
SHENKIN, A
GARDEN, OJ
机构
[1] University Department of Surgery, Royal Infirmary of Edinburgh, Edinburgh
关键词
D O I
10.1002/bjs.1800790516
中图分类号
R61 [外科手术学];
学科分类号
摘要
The evaluation of nutritional status in surgical patients remains a difficult problem. Bioelectrical impedance analysis (BIA) is a new method of body composition analysis which is easily performed at the bedside. This study determined the accuracy of BIA in the measurement of total body water (TBW) and potassium (TBK) in a heterogeneous group of surgical patients. The resistance and reactance components of impedance were measured with a whole body impedance analyser. Tritiated water dilution and whole body monitoring were the reference methods for TBW and TBK analysis. With the BIA technique the coefficient of variation for the estimation of TBW was 8.1 per cent and for TBK was 6.4 per cent. Allowing for the errors of the reference methods these results show that BIA is of limited value in the estimation of TBW but may provide a useful index of TBK.
引用
收藏
页码:421 / 423
页数:3
相关论文
共 15 条
[1]   MEASUREMENT OF TOTAL BODY POTASSIUM W2TH A SHADOW SHIELD WHOLE BODY COUNTER - CALIBRATION AND ERRORS [J].
BODDY, K ;
KING, PC ;
TOTHILL, P ;
STRONG, JA .
PHYSICS IN MEDICINE AND BIOLOGY, 1971, 16 (02) :275-&
[2]   FAILURE OF DELAYED-HYPERSENSITIVITY SKIN TESTING TO PREDICT POSTOPERATIVE SEPSIS AND MORTALITY [J].
BROWN, R ;
BANCEWICZ, J ;
HAMID, J ;
PATEL, NJ ;
WARD, CA ;
FARRAND, RJ ;
PUMPHREY, RSH ;
IRVING, M .
BRITISH MEDICAL JOURNAL, 1982, 284 (6319) :851-853
[3]  
BURKINSHAW L, 1990, INFUSIONSTHERAPIE, V17, P21
[4]   SURGICAL NUTRITION - TIME FOR SOME CLINICAL COMMON-SENSE [J].
HILL, GL .
BRITISH JOURNAL OF SURGERY, 1988, 75 (08) :729-730
[5]  
HILL GL, 1988, NUTR METAB, P89
[6]   BULK OR BOUNCE - THE OBJECT OF NUTRITIONAL SUPPORT [J].
JEEJEEBHOY, KN .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1988, 12 (06) :539-549
[7]   ESTIMATION OF TOTAL-BODY WATER BY BIOELECTRICAL IMPEDANCE ANALYSIS [J].
KUSHNER, RF ;
SCHOELLER, DA .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1986, 44 (03) :417-424
[8]   ASSESSMENT OF FAT-FREE MASS USING BIOELECTRICAL IMPEDANCE MEASUREMENTS OF THE HUMAN-BODY [J].
LUKASKI, HC ;
JOHNSON, PE ;
BOLONCHUK, WW ;
LYKKEN, GI .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1985, 41 (04) :810-817
[9]  
Moore FD, 1963, BODY CELL MASS ITS S, P19
[10]   BIOELECTRICAL IMPEDANCE ANALYSIS FOR BODY-COMPOSITION - CLINICAL-EVALUATION IN GENERAL SURGICAL PATIENTS [J].
SCHROEDER, D ;
CHRISTIE, PM ;
HILL, GL .
JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1990, 14 (02) :129-133