MEASUREMENT OF COLLAPSE CAVITATION IN ULTRASOUND FIELDS

被引:8
作者
DIGBY, M
DUCK, FA
LENZ, EJ
PRICE, GJ
机构
[1] ROYAL UNITED HOSP,DEPT MED PHYS,BATH BA1 3NG,AVON,ENGLAND
[2] UNIV BATH,SCH CHEM,BATH BA2 7DY,AVON,ENGLAND
关键词
D O I
10.1259/0007-1285-68-815-1244
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This note describes a method for the measurement of hydroxyl free radical concentration due to collapse acoustic cavitation in medical ultrasound fields using aqueous terephthalic acid (TA) solution. An enclosed cylindrical chamber with acoustically transparent membranes at either end was used. Control of cavitation activity was achieved by seeding the solution with polystyrene microspheres to provide cavitation centres. Insonation experiments using unseeded TA previously exposed to air gave very variable results, sometimes detecting cavitation activity and at other times detecting nothing, under the same exposure conditions. Introduction of polystyrene microsphere seeds into the TA enabled it to detect reproducibly levels of cavitation activity at least one order of magnitude higher that in unseeded solutions. An experiment using the seeded TA in a standing wave ultrasound field, set up using a brass reflecting plate, demonstrated that the presence of a standing wave inhibited the measured cavitation yield.
引用
收藏
页码:1244 / 1248
页数:5
相关论文
共 12 条
[1]   LYSIS OF ERYTHROCYTES BY EXPOSURE TO CW ULTRASOUND [J].
CARSTENSEN, EL ;
KELLY, P ;
CHURCH, CC ;
BRAYMAN, AA ;
CHILD, SZ ;
RAEMAN, CH ;
SCHERY, L .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (02) :147-165
[2]   EVIDENCE FOR FREE-RADICALS PRODUCED IN AQUEOUS-SOLUTIONS BY DIAGNOSTIC ULTRASOUND [J].
CHRISTMAN, CL ;
CARMICHAEL, AJ ;
MOSSOBA, MM ;
RIESZ, P .
ULTRASONICS, 1987, 25 (01) :31-34
[3]   EVIDENCE FOR FREE-RADICAL PRODUCTION BY ULTRASONIC CAVITATION IN BIOLOGICAL MEDIA [J].
EDMONDS, PD ;
SANCIER, KM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (06) :635-639
[4]   INVITRO DETECTION OF CAVITATION INDUCED BY A DIAGNOSTIC ULTRASOUND SYSTEM [J].
HOLLAND, CK ;
ROY, RA ;
APFEL, RE ;
CRUM, LA .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (01) :95-101
[5]   THRESHOLDS FOR TRANSIENT CAVITATION PRODUCED BY PULSED ULTRASOUND IN A CONTROLLED NUCLEI ENVIRONMENT [J].
HOLLAND, CK ;
APFEL, RE .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1990, 88 (05) :2059-2069
[6]  
Leighton T.J., 1994, ACOUSTIC BUBBLE
[7]   A CAVITATION AND FREE-RADICAL DOSIMETER FOR ULTRASOUND [J].
MCLEAN, JR ;
MORTIMER, AJ .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1988, 14 (01) :59-64
[8]   A COMPARISON OF HEMOLYTIC AND SONOCHEMICAL ACTIVITY OF ULTRASONIC CAVITATION IN A ROTATING TUBE [J].
MILLER, DL ;
THOMAS, RM .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1993, 19 (01) :83-90
[9]   FREQUENCY-DEPENDENCE OF CAVITATION ACTIVITY IN A ROTATING TUBE EXPOSURE SYSTEM COMPARED TO THE MECHANICAL INDEX [J].
MILLER, DL ;
THOMAS, RM .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (06) :3475-3480
[10]   MECHANISMS FOR HEMOLYSIS BY ULTRASONIC CAVITATION IN THE ROTATING EXPOSURE SYSTEM [J].
MILLER, DL ;
THOMAS, RM ;
WILLIAMS, AR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) :171-178