PEAK RESOLUTION IN THE DETERMINATION OF COBALT AND NICKEL BY DIFFERENTIAL PULSE AND ALTERNATING-CURRENT ADSORPTION VOLTAMMETRY

被引:28
作者
LOCATELLI, C [1 ]
FAGIOLI, F [1 ]
GARAI, T [1 ]
机构
[1] HUNGARIAN ACAD SCI,INORGAN CHEM RES LAB,H-1112 BUDAPEST,HUNGARY
关键词
D O I
10.1021/ac00014a013
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
The simultaneous determination of cobalt(II) and nickel(II) by differential pulse adsorption voltammetry and fundamental and second harmonic alternating current adsorption voltammetry was compared in the case of very high element concentration ratios. The measurements were carried out in 0.5 M ammonia buffer-1 x 10(-4) M dimethylglyoxime (DMG) as the supporting electrolyte, employing a semistationary mercury electrode with a drop time of 180-240 s (the long lasting sessile drop mercury electrode) as the working electrode. The accuracy of the analytical procedure was checked by the analysis of the standard reference materials: stainless steel (AISI 321) SRM 121-d and highly alloyed steel (Eurostandard 281-1). The precision, expressed as the relative standard deviation, and the detection limits were also reported for each voltammetric technique. The selectivity of the above-mentioned three techniques was found to increase in the following order: second harmonic alternating current adsorption voltammetry > differential pulse adsorption voltammetry > fundamental harmonic alternating current adsorption voltammetry.
引用
收藏
页码:1409 / 1413
页数:5
相关论文
共 39 条
[1]
ASSESSMENT OF DIFFERENTIAL-PULSE ADSORPTION VOLTAMMETRY FOR THE SIMULTANEOUS DETERMINATION OF NICKEL AND COBALT IN BIOLOGICAL-MATERIALS [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :181-194
[2]
MULTIELEMENT DETERMINATION IN BIOLOGICAL-MATERIALS BY DIFFERENTIAL PULSE VOLTAMMETRY [J].
ADELOJU, SB ;
BOND, AM ;
BRIGGS, MH .
ANALYTICAL CHEMISTRY, 1985, 57 (07) :1386-1390
[3]
VOLTAMMETRIC DETERMINATION OF TRACES OF NICKEL(II) AT A CHEMICALLY MODIFIED ELECTRODE BASED ON DIMETHYLGLYOXIME-CONTAINING CARBON PASTE [J].
BALDWIN, RP ;
CHRISTENSEN, JK ;
KRYGER, L .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1790-1798
[5]
BOND AM, 1980, MODERN POLAROGRAPHIC, pCH7
[6]
ANALYTICAL DETERMINATION OF NICKEL IN THE ENVIRONMENT BY ADSORPTION VOLTAMMETRY USING THE MERCURY FILM ELECTRODE [J].
BRAUN, H ;
METZGER, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 318 (05) :321-326
[7]
DETERMINATION OF COBALT IN THE PRESENCE OF NICKEL AND OTHER METALS BY DIFFERENTIAL PULSE POLAROGRAPHY IN SOLUTIONS CONTAINING DIMETHYLGLYOXIME AND CITRATE [J].
CHEN, H ;
NEEB, R .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1983, 314 (07) :657-659
[8]
ELECTROCHEMICAL BEHAVIOR OF THE NICKEL(II) ION AT THE DROPPING MERCURY-ELECTRODE IN THE PRESENCE OF SOME COMPLEXING AGENTS .1. [J].
CROW, DR ;
ROSE, ME .
ELECTROCHIMICA ACTA, 1979, 24 (01) :41-45
[9]
DETERMINATION OF COBALT ON SURFACTANT-MODIFIED MERCURY-ELECTRODES [J].
EMONS, H ;
SCHMIDT, T ;
WERNER, G .
ANALYTICA CHIMICA ACTA, 1990, 228 (01) :55-60
[10]
DETERMINATION OF NICKEL AND COBALT IN NATURAL-WATERS AND BIOLOGICAL-MATERIAL BY REDUCTIVE CHRONOPOTENTIOMETRIC STRIPPING ANALYSIS IN A FLOW SYSTEM WITHOUT SAMPLE DEOXYGENATION [J].
ESKILSSON, H ;
HARALDSSON, C ;
JAGNER, D .
ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) :79-88