MEASUREMENT OF NORMAL RENAL-ARTERY BLOOD-FLOW - CINE PHASE-CONTRAST MR-IMAGING VS CLEARANCE OF P-AMINOHIPPURATE

被引:49
作者
WOLF, RL
KING, BF
TORRES, VE
WILSON, DM
EHMAN, RL
机构
[1] MAYO CLIN & MAYO FDN, DEPT DIAGNOST RADIOL, 200 1ST ST SW, ROCHESTER, MN 55905 USA
[2] MAYO CLIN & MAYO FDN, DEPT NEPHROL, ROCHESTER, MN 55905 USA
关键词
D O I
10.2214/ajr.161.5.8273644
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare cine phase-contrast MR imaging with renal clearance of p-aminohippurate for measuring normal renal blood flow. A reliable technique for evaluation of renal hemodynamics would be useful for studying renal vascular diseases and the effects of treatment. Measurements of renal blood flow based on renal clearance of p-aminohippurate are limited in that the kidneys are not studied separately, temporal resolution is poor, and normal renal function is required. SUBJECTS AND METHODS. Bilateral oblique sagittal cine phase-contrast MR images were obtained simultaneously in 10 healthy adult volunteers, with the imaging planes oriented perpendicular to the left and right renal arteries in order to measure through-plane flow. Velocity encoding was 150 cm/sec (seven of 10 volunteers) and 100 cm/sec (eight of 10 volunteers). Axial cine phase-contrast images of the abdominal aorta above and below the origins of the renal arteries were obtained in six volunteers. In these cases, renal blood flow was determined by measuring the difference between suprarenal and infrarenal aortic flow. For all volunteers, renal clearance of p-aminohippurate was determined immediately after MR measurements. RESULTS. Renal blood flow measurements determined by using cine phase-contrast MR imaging were in close agreement with those determined by using clearance of p-aminohippurate. At a velocity encoding of 150 cm/sec, the mean difference was 69 ml/min (95% confidence interval, -31 to 169 ml/min). At a velocity encoding of 100 cm/sec, the mean difference was 39 ml/min (95% confidence interval, -100 to 177 ml/min). Aortic flow measurements using cine phase-contrast MR imaging appeared to be less reliable for determining renal blood flow than measurements in the individual renal arteries, with a mean difference of -75 ml/min (95% confidence interval, -381 to 231 ml/min) compared with renal blood flow determined by using clearance of p-aminohippurate. CONCLUSION. We conclude that cine phase-contrast MR imaging is a promising technique for noninvasive measurement of renal blood flow. Measurements agreed closely with those obtained by using clearance of p-aminohippurate. In addition, the MR technique is faster, can be used to measure unilateral or bilateral renal blood flow, and does not depend on renal function.
引用
收藏
页码:995 / 1002
页数:8
相关论文
共 28 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   FACTORS INFLUENCING THE ACCURACY AND PRECISION OF VELOCITY-ENCODED PHASE IMAGING [J].
BUONOCORE, MH ;
BOGREN, H .
MAGNETIC RESONANCE IN MEDICINE, 1992, 26 (01) :141-154
[3]   RIGHT AND LEFT LUNG PERFUSION - INVITRO AND INVIVO VALIDATION WITH OBLIQUE-ANGLE, VELOCITY-ENCODED CINE MR IMAGING [J].
CAPUTO, GR ;
KONDO, C ;
MASUI, T ;
GERACI, SJ ;
FOSTER, E ;
OSULLIVAN, MM ;
HIGGINS, CB .
RADIOLOGY, 1991, 180 (03) :693-698
[4]  
Duarte CG, 1980, RENAL FUNCTION TESTS
[5]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[6]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[7]   DETECTION OF SEA-WATER MOTION BY NUCLEAR PRECESSION [J].
HAHN, EL .
JOURNAL OF GEOPHYSICAL RESEARCH, 1960, 65 (02) :776-777
[8]   RENAL DUPLEX SONOGRAPHY - EVALUATION OF CLINICAL UTILITY [J].
HANSEN, KJ ;
TRIBBLE, RW ;
REAVIS, SW ;
CANZANELLO, VJ ;
CRAVEN, TE ;
PLONK, GW ;
DEAN, RH .
JOURNAL OF VASCULAR SURGERY, 1990, 12 (03) :227-236
[9]   ROLE OF DUPLEX SCANNING FOR THE DETECTION OF ATHEROSCLEROTIC RENAL-ARTERY DISEASE [J].
HOFFMANN, U ;
EDWARDS, JM ;
CARTER, S ;
GOLDMAN, ML ;
HARLEY, JD ;
ZACCARDI, MJ ;
STRANDNESS, DE .
KIDNEY INTERNATIONAL, 1991, 39 (06) :1232-1239
[10]   RENAL VASCULATURE IN EARLY ESSENTIAL HYPERTENSION - EVIDENCE FOR A PATHOGENETIC ROLE [J].
HOLLENBERG, NK ;
BORUCKI, LJ ;
ADAMS, DF .
MEDICINE, 1978, 57 (02) :167-178