INSTRUMENTAL DEVELOPMENTS IN ORGANIC MASS-SPECTROMETRY

被引:8
作者
LINSCHEID, M
机构
[1] ISAS-Institut für Spektrochemie, Dortmund 1, D-4600
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1990年 / 337卷 / 06期
关键词
D O I
10.1007/BF00323099
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Mass spectrometry is a conglomerate of numerous technical and methodological approaches and recently, new developments in all its fields occur rather frequent. The stimulation has at least two different major sources: on the one hand the requirements in environmental analytical chemistry enforce an increasing sensitivity accompanied by the necessity to construct small, affordable spectrometers. On the other hand, modern biochemistry needs not only sensitivity, but new, compatible inlet techniques to solve the analytical problems in biotechnology, molecular biology and medical sciences. Consequently, small detectors for gas and liquid chromatography with almost inconceivable sensitivity and high performance spectrometers to handle large molecules up to several ten thousand daltons have been developed. New desorption techniques with atom and ion beams or lasers have been designed, several new chromatographic techniques are now compatible with MS, only to name capillary zone electrophoresis, isotachophoresis and even thin layer chromatography. Todays analyzers are small quadrupoles or ion traps, time of flight instruments, ion cyclotrons or arrangement of electrostatic and magnetic sector fields in numerous possible orders and combinations (MS/MS). Very recently, even the detector systems experience a revolution from the electron multipliers to simultaneous detection systems based on array detector devices, which improves the detection capability by orders of magnitude particularly for the analysis of large molecules such as biopolymers. © 1990 Springer-Verlag.
引用
收藏
页码:648 / 661
页数:14
相关论文
共 71 条
  • [21] FAST HEAVY-ION INDUCED DESORPTION OF BIOMOLECULES
    HAKANSSON, P
    KAMENSKY, I
    SUNDQVIST, B
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 198 (01): : 43 - 51
  • [22] HILLENKAMP F, 1981, FRESENIUS Z ANAL CHE, V308
  • [23] NEW PICOGRAM DETECTION SYSTEM BASED ON A MASS-SPECTROMETER WITH AN EXTERNAL IONIZATION SOURCE AT ATMOSPHERIC-PRESSURE
    HORNING, EC
    HORNING, MG
    CARROLL, DI
    DZIDIC, I
    STILLWELL, RN
    [J]. ANALYTICAL CHEMISTRY, 1973, 45 (06) : 936 - 943
  • [24] 1ST DEMONSTRATION OF HIGH-RESOLUTION LASER DESORPTION MASS-SPECTROMETRY OF HIGH MASS ORGANIC IONS
    IJAMES, CF
    WILKINS, CL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) : 2687 - 2688
  • [25] On the evaporation of small ions from charged droplets
    IRIBARNE, JV
    THOMSON, BA
    [J]. JOURNAL OF CHEMICAL PHYSICS, 1976, 64 (06) : 2287 - 2294
  • [26] TANDEM MASS-SPECTROMETRY FOR TRACE ANALYSIS
    JOHNSON, JV
    YOST, RA
    [J]. ANALYTICAL CHEMISTRY, 1985, 57 (07) : A758 - &
  • [27] A HIGH INTENSITY SOURCE FOR THE MOLECULAR BEAM .1. THEORETICAL
    KANTROWITZ, A
    GREY, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (05) : 328 - 332
  • [28] KARAS K, 1989, ANGEW CHEM, V101, P805
  • [29] A HIGH INTENSITY SOURCE FOR THE MOLECULAR BEAM .2. EXPERIMENTAL
    KISTIAKOWSKY, GB
    SLICHTER, WP
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1951, 22 (05) : 333 - 337
  • [30] TIME-OF-FLIGHT ICR SPECTROMETRY
    KOFEL, P
    ALLEMANN, M
    KELLERHALS, H
    WANCZEK, KP
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1986, 72 (1-2): : 53 - 61