AUTORADIOGRAPHY FOR I-125 SEEDS

被引:8
作者
ALBERTI, W
DIVOUX, S
POTHMANN, B
TABOR, P
HERMANN, KP
HARDER, D
机构
[1] UNIV ESSEN GESAMTHSCH,STRAHLEN KLIN,KLINIKUM,W-4300 ESSEN 1,GERMANY
[2] UNIV GOTTINGEN,INST MED PHYS & BIOPHYS,W-3400 GOTTINGEN,GERMANY
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1993年 / 25卷 / 05期
关键词
IODINE; 125; SEEDS; DOSIMETRY; AUTORADIOGRAPHY; OPHTHALMIC PLAQUE;
D O I
10.1016/0360-3016(93)90319-Q
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
To study the interior design of model 6702 and 6711 iodine-125 seeds contact autoradiographs were performed using mammography film. Improved resolution was obtained using a pin-hole camera with a hole of 0.1 mm x 0.1 mm. With these techniques, qualitative determination of the relative activity distribution within each seed was possible. The number of the activated resin spheres and the positions of the centers of these spheres can be exactly determined. A model calculation shows, that variations in the arrangement of the activated spheres within a seed have a moderate influence on the dose distribution at source distances below 10 mm. Knowing the exact source configuration may be useful when comparing dose calculations with measured data for model 6702 I-125 seeds which are currently employed in ophthalmic plaque and implant therapy of other tumors.
引用
收藏
页码:881 / 884
页数:4
相关论文
共 16 条
[1]   DOSIMETRY AND PHYSICAL TREATMENT PLANNING FOR IODINE EYE PLAQUE THERAPY [J].
ALBERTI, W ;
POTHMANN, B ;
TABOR, P ;
MUSKALLA, K ;
HERMANN, KP ;
HARDER, D .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 20 (05) :1087-1092
[2]  
ANDERSON LL, 1990, INTERSTITIAL BRACHYT, P75
[3]   AN INTERACTIVE TREATMENT PLANNING SYSTEM FOR OPHTHALMIC PLAQUE RADIOTHERAPY [J].
ASTRAHAN, MA ;
LUXTON, G ;
JOZSEF, G ;
KAMPP, TD ;
LIGGETT, PE ;
SAPOZINK, MD ;
PETROVICH, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (03) :679-687
[4]   TWO-DIMENSIONAL DOSE DISTRIBUTION AROUND A COMMERCIAL I125 SEED [J].
BURNS, GS ;
RAESIDE, DE .
MEDICAL PHYSICS, 1988, 15 (01) :56-60
[5]   DOSE-RATE DETERMINATION FOR I-125 SEEDS [J].
CHIUTSAO, ST ;
ANDERSON, LL ;
OBRIEN, K ;
SANNA, R .
MEDICAL PHYSICS, 1990, 17 (05) :815-825
[6]   AN I-125 PLAQUE FOR RADIOTHERAPY OF THE EYE - MANUFACTURE AND DOSIMETRIC CONSIDERATIONS [J].
HARNETT, AN ;
THOMSON, ES .
BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (729) :835-838
[7]   AN I-125 APPLICATOR DESIGNED FOR IRRADIATING BLOOD-VESSELS GROWING INTO THE CORNEA OF THE EYE [J].
HERING, ER ;
SEALY, R ;
KORRUBEL, JB ;
HILL, J .
BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (735) :266-268
[8]   DOSIMETRIC CALCULATIONS AND MEASUREMENTS OF GOLD PLAQUE OPHTHALMIC IRRADIATORS USING IR-192 AND I-125 SEEDS [J].
LUXTON, G ;
ASTRAHAN, MA ;
LIGGETT, PE ;
NEBLETT, DL ;
COHEN, DM ;
PETROVICH, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (01) :167-176
[9]   BACKSCATTER MEASUREMENTS FROM A SINGLE SEED OF I125 FOR OPHTHALMIC PLAQUE DOSIMETRY [J].
LUXTON, G ;
ASTRAHAN, MA ;
PETROVICH, Z .
MEDICAL PHYSICS, 1988, 15 (03) :397-400
[10]   A COMPARISON OF SOLID PHANTOMS WITH WATER FOR DOSIMETRY OF I125 BRACHYTHERAPY SOURCES [J].
MEIGOONI, AS ;
MELI, JA ;
NATH, R .
MEDICAL PHYSICS, 1988, 15 (05) :695-701