LARGE-VOLUME HEMOCYTOMETER CHAMBER FOR ACCURATE COUNTING OF WHITE CELLS (WBCS) IN WBC-REDUCED PLATELETS - VALIDATION AND APPLICATION FOR QUALITY-CONTROL OF WBC-REDUCED PLATELETS PREPARED BY APHERESIS AND FILTRATION

被引:71
作者
LUTZ, P [1 ]
DZIK, WH [1 ]
机构
[1] HARVARD UNIV,SCH MED,DEPT MED,BOSTON,MA 02115
关键词
D O I
10.1046/j.1537-2995.1993.33593255602.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A detailed description is provided of a method using a large-volume (50 muL) hemocytometer to count very low numbers of white cells (WBCs) in platelet components. A method employing a Nageotte hemocytometer uses crystal violet stain and a standard microscope with a reading time of 5 to 10 minutes. .The method is validated by using serial dilutions of known concentrations of WBCs in platelets and by correlation with a flow cytometric technique. The interobserver coefficient of variation was 11.9 percent for WBC concentrations >2 per muL. Use of the method for the evaluation of 203 WBC-reduced platelet components prepared by apheresis or by filtration revealed that over 94 percent of components had WBC content <5 x 10(6) This method could easily be applied in the routine quality control of WBC-reduced platelet components and in clinical studies employing these components.
引用
收藏
页码:409 / 412
页数:4
相关论文
共 12 条