FLOW-THROUGH PH-ISFET AS DETECTOR IN AUTOMATED DETERMINATIONS

被引:13
作者
ALEGRET, S
BARTROLI, J
JIMENEZ, C
DELVALLE, M
DOMINGUEZ, C
CABRUJA, E
MERLOS, A
机构
[1] UNIV AUTONOMA BARCELONA,DEPT QUIM,E-08193 BARCELONA,SPAIN
[2] UNIV AUTONOMA BARCELONA,CSIC,CTR NACL MICROELECTR,E-08193 BARCELONA,SPAIN
关键词
D O I
10.1002/elan.1140030417
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The implementation of a pH-ISFET (ion-selective field effect transistor) planar chip in a flow-injection system by means of a specially designed flow cell and the application of the sensor to the analysis of volatile compounds is described. Ammonia and sulfur dioxide are determined by exploiting the advantages of the flow techniques combined with continuous gas diffusion. Initial species are converted to gaseous compounds, which diffuse through a microporous hydrophobic membrane into an ammonium chloride or hydrogen sulfite recipient stream, producing a pH variation that is monitored by the semiconductor detector. The linear working range extends from 1 x 10(-2) to 1 x 10(-4) M for the ammonium system and from 4 x 10(-3) to 7 x 10(-5) for the sulfur dioxide system, with relative standard deviation of about 1 and 0.5%, respectively.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 16 条
[1]   FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC ;
PAULIS, JM .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18) :2291-2303
[2]   FLOW-THROUGH PH-ISFET AS DETECTOR IN THE DETERMINATION OF AMMONIA [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
DELVALLE, M ;
JAFFREZICRENAULT, N ;
DUVAULTHERRERA, Y .
ANALYTICA CHIMICA ACTA, 1990, 231 (01) :53-58
[3]   FLOW-INJECTION SYSTEM FOR ONLINE POTENTIOMETRIC MONITORING OF AMMONIA IN FRESH-WATER STREAMS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
MARTINEZFABREGAS, E .
ANALYST, 1989, 114 (11) :1443-1447
[4]   PH-ISFET WITH NMOS TECHNOLOGY [J].
ALEGRET, S ;
BARTROLI, J ;
JIMENEZ, C ;
DELVALLE, M ;
DOMINGUEZ, C ;
CABRUJA, E ;
MERLOS, A .
ELECTROANALYSIS, 1991, 3 (4-5) :355-360
[5]   FLOW-THROUGH PH-ISFET DETECTOR FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
DOMENECH, J ;
JAFFREZICRENAULT, N ;
DUVAULTHERRERA, Y .
ANALYTICA CHIMICA ACTA, 1989, 222 (02) :373-377
[6]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[7]   DETERMINATION OF SULFUR-DIOXIDE BY FLOW-INJECTION ANALYSIS WITH AMPEROMETRIC DETECTION [J].
GRANADOS, M ;
MASPOCH, S ;
BLANCO, M .
ANALYTICA CHIMICA ACTA, 1986, 179 :445-451
[8]  
HANG GH, 1989, SENSOR ACTUATOR, V19, P41
[9]   FLOW INJECTION ANALYSIS FOR CALCIUM IN SERUM, WATER AND WASTE-WATERS BY SPECTROPHOTOMETRY AND BY ION-SELECTIVE ELECTRODE [J].
HANSEN, EH ;
RUZICKA, J ;
GHOSE, AK .
ANALYTICA CHIMICA ACTA, 1978, 100 (SEP) :151-165
[10]  
LEE HL, 1985, ANALYST, V110, P371, DOI 10.1039/an9851000371