TRACER-GAS TECHNIQUES FOR MEASURING VENTILATION IN A SINGLE ZONE

被引:224
作者
SHERMAN, MH
机构
[1] Energy Performance of Buildings Group, Applied Science Division, Lawrence Berkeley Laboratory, Berkeley
关键词
Gas Injection Strategies - Tracer Gases;
D O I
10.1016/0360-1323(90)90010-O
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Tracer-gas techniques have become widely used to measure the ventilation rates in buildings. A tracer gas is an idealized substance used to tag volumes of air so as to be able to infer their bulk movement; the properties of a perfect tracer are discussed. The basic principle involved is that of conservation of mass (of both air and tracer gas) as expressed in the continuity equation; by monitoring the injection and concentration of the tracer, one can infer the exchange of air. This report will summarize the techniques in use. Although there is only one continuity equation, there are many different experimental injection strategies and analytical approaches. These different techniques may result in different estimates of ventilation due to uncertainties and biases of the procedures. This report will analyse the spectrum of techniques, including some of the relevant error analyses. © 1990.
引用
收藏
页码:365 / 374
页数:10
相关论文
共 32 条
[1]  
Hitchin, Wilson, Review of experimental techniques for the investigation of natural ventilation in buildings, Bldg Sci., 2, pp. 59-82, (1967)
[2]  
Hunt, Air infiltration: a review of existing measurement techniques and data, Building Air Change Rate and Infiltration Measurements, (1980)
[3]  
Sherman, Grimsrud, Condon, Smith, Air infiltration measurement techniques, Proceedings of the 1st AIC Conference on Air Infiltration Instrumentation and Measuring Techniques, (1980)
[4]  
Sherman, Grimsrud, Condon, Smith, Lawrence Berkeley Laboratory LBL-10705, (1980)
[5]  
Lagus, Air leakage measurements by the tracer dilution method—a review, Building Air Change Rate and Infiltration Measurements, (1980)
[6]  
Singer, Helium leak detection in vacuum systems and IC packages, Semicond. Int., 10, 11, pp. 51-55, (1987)
[7]  
McCullough, Leak testing, ASTM Stand. News, 10, 11, pp. 32-33, (1982)
[8]  
Ferber, Telegadas, Heffter, Et al., Demonstrations of a long-range atmospheric tracer system using perfluorocarbons, BNL-33846, (1983)
[9]  
Lagus, Persily, A review of tracer gas techniques for measuring airflows in building, ASHRAE Trans. IIB, 91, pp. 1075-1087, (1985)
[10]  
Warner, Measurements of the ventilation of dwellings, Journal of Hygiene, 40, pp. 125-150, (1940)