INFLUENCE OF PLASTICIZER ON THE SELECTIVITY OF NITRATE-SENSITIVE CHEMFETS

被引:40
作者
STAUTHAMER, WPRV [1 ]
ENGBERSEN, JFJ [1 ]
VERBOOM, W [1 ]
REINHOUDT, DN [1 ]
机构
[1] UNIV TWENTE,MESA INST,DEPT ORGAN CHEM,POB 217,7500 AE ENSCHEDE,NETHERLANDS
关键词
D O I
10.1016/0925-4005(93)00870-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By chemical modification of an ion-sensitive field-effect transistor, a sensor (CHEMFET) has been developed whose sensitivity for nitrate has been tested. A plasticized poly(vinyl chloride) (PVC) membrane, which contains lipophilic tetra-n-octyl-ammonium ions, is responsible for the nitrate sensitivity of the device. This membrane has been attached physically on top of a pH-buffered hydrogel, which itself has been attached covalently to the gate oxide of the field-effect transistor. The influence of the plasticizer in the PVC membrane on the selectivity pattern of the CHEMFET for the detection of nitrate has been investigated.
引用
收藏
页码:197 / 201
页数:5
相关论文
共 35 条
[1]   ANALYTICAL-CHEMISTRY IN NUCLEAR TECHNOLOGY [J].
ACHE, HJ .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 343 (11) :852-862
[2]   CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS - A SODIUM-ION SELECTIVE SENSOR BASED ON CALIX[4]ARENE RECEPTOR MOLECULES [J].
BRUNINK, JAJ ;
HAAK, JR ;
BOMER, JG ;
REINHOUDT, DN ;
MCKERVEY, MA ;
HARRIS, SJ .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :75-80
[3]  
BRUNINK JAJ, 1993, ANAL CHIM ACTA, V271, P135
[4]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582
[5]   RECENT ADVANCES IN MICROELECTRONIC ION-SENSITIVE DEVICES (ISFETS) - THE OPERATIONAL TRANSDUCER [J].
COVINGTON, AK ;
WHALLEY, PD .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS I, 1986, 82 :1209-&
[6]   CHLORIDE CHEMICAL SENSOR BASED ON AN ORGANIC CONDUCTING POLYPYRROLE POLYMER [J].
DONG, SJ ;
SUN, ZS ;
LU, ZL .
ANALYST, 1988, 113 (10) :1525-1528
[7]   SELECTRODE - UNIVERSAL ION-SELECTIVE ELECTRODE .7. VALINOMYCIN-BASED POTASSIUM ELECTRODE WITH NONPOROUS POLYMER MEMBRANE AND SOLID-STATE INNER REFERENCE SYSTEM [J].
FIEDLER, U ;
RUZICKA, J .
ANALYTICA CHIMICA ACTA, 1973, 67 (01) :179-193
[8]   A NEW LIQUID-MEMBRANE ELECTRODE FOR SELECTIVE DETERMINATION OF PERCHLORATE [J].
HASSAN, SSM ;
ELSAIED, MM .
TALANTA, 1986, 33 (08) :679-684
[9]   FLUORIDE SOLVATION - THE CASE OF THE MISSING ION [J].
HEFTER, GT .
PURE AND APPLIED CHEMISTRY, 1991, 63 (12) :1749-1758
[10]  
HOFMEISTER F, 1888, N-S ARCH EXP PATH PH, V24, P247