ION-SPRAY MASS-SPECTROMETRIC DETECTION FOR LIQUID-CHROMATOGRAPHY - A CONCENTRATION-FLOW-SENSITIVE OR A MASS-FLOW-SENSITIVE DEVICE

被引:129
作者
HOPFGARTNER, G
BEAN, K
HENION, J
HENRY, R
机构
[1] CORNELL UNIV,NEW YORK STATE COLL VET MED,925 WARREN DR,ITHACA,NY 14850
[2] KEYSTONE SCI INC,BELLEFONTE,PA 16823
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 647卷 / 01期
关键词
D O I
10.1016/0021-9673(93)83323-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the mass spectrometer becomes more accepted as a detector for HPLC, its characteristics should become better understood by those performing routine LC-MS experiments. In particular, the ion current response for quantitative analysis studies involving significant dynamic range in concentration for target analytes must be determined as well as other factors that affect MS response. This work describes the concentration-sensitive response for the ion spray (pneumatically-assisted electrospray) LC-MS interface from the chromatographer's perspective. A comparison of LC-MS ion current response in the isocratic mode resulting from studies of a synthetic mixture containing alkyl benzoates is presented. LC-MS total ion current chromatograms from three different column sizes (1 mm I.D., 2.1 mm I.D. and 4.6 mm I.D.) with and without a post-column split, and high-flow ion spray LC-MS without a post-column split illustrates that the former behaves as a concentration-sensitive detector whereas the latter behaves as a mass-flow-sensitive detector. The flexibility of ion spray to high-flow applications allows the use of HPLC eluent flow ranging from 0.001-2.0 ml/min. The use of solvent-buffer post-column addition also allows optimization for improved analyte ion current response.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 19 条
[1]   COMBINED LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY .3. APPLICATIONS OF THERMOSPRAY [J].
ARPINO, P .
MASS SPECTROMETRY REVIEWS, 1992, 11 (01) :3-40
[2]   VARIABLES AFFECTING PRECISION AND ACCURACY IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BAKALYAR, SR ;
HENRY, RA .
JOURNAL OF CHROMATOGRAPHY, 1976, 126 (NOV3) :327-345
[3]   MASS-SPECTROMETRY WITH ION SOURCES OPERATING AT ATMOSPHERIC-PRESSURE [J].
BRUINS, AP .
MASS SPECTROMETRY REVIEWS, 1991, 10 (01) :53-77
[4]   ION SPRAY INTERFACE FOR COMBINED LIQUID CHROMATOGRAPHY/ATMOSPHERIC PRESSURE IONIZATION MASS-SPECTROMETRY [J].
BRUINS, AP ;
COVEY, TR ;
HENION, JD .
ANALYTICAL CHEMISTRY, 1987, 59 (22) :2642-2646
[5]   AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETER WITH NEW FEATURES [J].
CHOWDHURY, SK ;
KATTA, V ;
CHAIT, BT .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1990, 4 (03) :81-87
[6]   CONCENTRATION + MASS FLOW RATE SENSITIVE DETECTORS IN GAS CHROMATOGRAPHY [J].
HALASZ, I .
ANALYTICAL CHEMISTRY, 1964, 36 (08) :1428-&
[7]   HIGH-FLOW ION SPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
HOPFGARTNER, G ;
WACHS, T ;
BEAN, K ;
HENION, J .
ANALYTICAL CHEMISTRY, 1993, 65 (04) :439-446
[8]   ELECTROSPRAY ION SPRAY - A COMPARISON OF MECHANISMS AND PERFORMANCE [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1989-1998
[9]   A CHROMATOGRAPHIC PERSPECTIVE OF HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
KARGER, BL ;
VOUROS, P .
JOURNAL OF CHROMATOGRAPHY, 1985, 323 (01) :13-32
[10]   ROLE OF COLUMN PARAMETERS AND INJECTION VOLUME ON DETECTION LIMITS IN LIQUID-CHROMATOGRAPHY [J].
KARGER, BL ;
MARTIN, M ;
GUIOCHON, G .
ANALYTICAL CHEMISTRY, 1974, 46 (12) :1640-1647