ION-SPRAY MASS-SPECTROMETRIC DETECTION FOR LIQUID-CHROMATOGRAPHY - A CONCENTRATION-FLOW-SENSITIVE OR A MASS-FLOW-SENSITIVE DEVICE

被引:129
作者
HOPFGARTNER, G
BEAN, K
HENION, J
HENRY, R
机构
[1] CORNELL UNIV,NEW YORK STATE COLL VET MED,925 WARREN DR,ITHACA,NY 14850
[2] KEYSTONE SCI INC,BELLEFONTE,PA 16823
来源
JOURNAL OF CHROMATOGRAPHY | 1993年 / 647卷 / 01期
关键词
D O I
10.1016/0021-9673(93)83323-K
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As the mass spectrometer becomes more accepted as a detector for HPLC, its characteristics should become better understood by those performing routine LC-MS experiments. In particular, the ion current response for quantitative analysis studies involving significant dynamic range in concentration for target analytes must be determined as well as other factors that affect MS response. This work describes the concentration-sensitive response for the ion spray (pneumatically-assisted electrospray) LC-MS interface from the chromatographer's perspective. A comparison of LC-MS ion current response in the isocratic mode resulting from studies of a synthetic mixture containing alkyl benzoates is presented. LC-MS total ion current chromatograms from three different column sizes (1 mm I.D., 2.1 mm I.D. and 4.6 mm I.D.) with and without a post-column split, and high-flow ion spray LC-MS without a post-column split illustrates that the former behaves as a concentration-sensitive detector whereas the latter behaves as a mass-flow-sensitive detector. The flexibility of ion spray to high-flow applications allows the use of HPLC eluent flow ranging from 0.001-2.0 ml/min. The use of solvent-buffer post-column addition also allows optimization for improved analyte ion current response.
引用
收藏
页码:51 / 61
页数:11
相关论文
共 19 条
[11]   MICRO-LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY WITH DIRECT LIQUID INTRODUCTION [J].
LEE, ED ;
HENION, JD .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1985, 23 (06) :253-264
[12]  
LONG GL, 1983, ANAL CHEM, V55, pA713
[13]   DETERMINATION OF CORTISOL IN SERUM BY USE OF COLUMN LIQUID CHROMATOGRAPHY [J].
MEIJERS, CAM ;
HUBER, JFK ;
HULSMAN, ARJ .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1972, 261 (4-5) :347-&
[14]   STRATEGIES IN DEVELOPING INTERFACES FOR COUPLING LIQUID-CHROMATOGRAPHY AND MASS-SPECTROMETRY [J].
NIESSEN, WMA ;
TJADEN, UR ;
VANDERGREEF, J .
JOURNAL OF CHROMATOGRAPHY, 1991, 554 (1-2) :3-26
[15]   FACTORS AFFECTING THE IONIZATION EFFICIENCY OF QUATERNARY AMMONIUM-COMPOUNDS IN ELECTROSPRAY IONSPRAY MASS-SPECTROMETRY [J].
RAFFAELLI, A ;
BRUINS, AP .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (06) :269-275
[16]  
SHEN S, 1992, 40TH P ASMS C MASS S
[17]   POSTCOLUMN ADDITION OF BUFFER FOR THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY IDENTIFICATION OF PESTICIDES [J].
VOYKSNER, RD ;
BURSEY, JT ;
PELLIZZARI, ED .
ANALYTICAL CHEMISTRY, 1984, 56 (08) :1507-1514
[18]   PERFORMANCE OF AN IMPROVED MONODISPERSE AEROSOL GENERATION INTERFACE FOR LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY [J].
WINKLER, PC ;
PERKINS, DD ;
WILLIAMS, WK ;
BROWNER, RF .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :489-493
[19]   MULTIPLE CHARGING IN ELECTROSPRAY IONIZATION OF POLY(ETHYLENE GLYCOLS) [J].
WONG, SF ;
MENG, CK ;
FENN, JB .
JOURNAL OF PHYSICAL CHEMISTRY, 1988, 92 (02) :546-550