A prospective in vivo study of 50 intraocular lenses was done to document the long-term results and biocompatibility of heparin-surface-modified poly(methyl methacrylate) posterior chamber lenses. Continuous curvilinear capsulorhexis and phacoemulsification were performed throughout and examinations were by slit-lamp and specular microscopy. Decentrations of more than 1 mm were seen in 4% of eyes. Stress folds from the haptic traction forces were detected in 16%. A posterior capsulotomy was performed in 1 0% because of fibrosis or Elschnig pearl formation. Fine fibers were found on the lens surface in 76%. During the first postoperative days only a moderate number of fibroblast-like cells was observed. Foreign-body giant cells were seen in 8%. All cases with foreign-body giant cells had posterior synechias. Visual performance and clinical results were comparable to those of other well-approved intraocular lenses. The low percentage of cellular reaction on the lens surface suggests good biocompatibility.
引用
收藏
页码:258 / 262
页数:5
相关论文
共 22 条
  • [1] Jacobi KW, Nowak MR, Neue Materialien bei Intraokularlinsen, Fortschr Ophthalmol, 86, pp. 203-205, (1989)
  • [2] Wenzel M, Reim M, Heinze M, Bucking A, Cellular invasion on the surface of intraocular lenses: In vivo cytological observations following lens implantation, Graefes Arch Clin Exp Ophthalmol, 226, pp. 449-454, (1988)
  • [3] Amon M, Menapace R, Cellular invasion on hydrogel and poly(methyl methacrylate) implants: An in vivo study, J Cataract Refract Surg, 17, pp. 774-779, (1991)
  • [4] Uenoyama K, Kanagawa R, Tamura M, Et al., Experimental intraocular lens implantation in the rabbit eye and in the mouse peritoneal space: Part IV: Cell adhesion, fibroblast-like cell, and lymphocytic cluster observed on the implanted lens surface, J Cataract Refract Surg, 15, pp. 559-566, (1989)
  • [5] Amon M, Menapace R, Beurteilung der biologischen Vertraglichkeit von PMMA-, heparinmodifizierten- PMMAund Hydrogel-Intraokularlinsen mit Hilfe der Spiegelmik roskopie, Klin Monatsbl Augenheilkd, 200, pp. 95-100, (1992)
  • [6] Ygge J, Wenzel M, Philipson B, Fagerholm P, Cellular reactions on heparin surface-modified versus regular PMMA lenses during the first postoperative month
  • [7] A double-masked and randomized study using specular microphotography, Ophthalmology, 97, pp. 1216-1224, (1990)
  • [8] Spangberg M, Kihlstrom I, Bjorklund H, Et al., Improved biocompatibility of intraocular lenses by heparin surface modification: A 12-month implantation study in monkeys, J Cataract Refract Surg, 16, pp. 170-177, (1990)
  • [9] Okada K, Tobari I, Postoperative cellular reaction on surface modified intraocular lenses in living human eyes, J Cataract Refract Surg, 17, pp. 319-323, (1991)
  • [10] Philipson B, Fagerholm P, Calel B, Et al., Heparin surface modified intraocular lenses-a one-year follow-up of a safety study, Acta Ophthalmol, 68, pp. 601-603, (1990)